-2 - For more information, visit www.desatech.comINTRODUCTIONBEFORE BEGINNING THE INSTALLATION OF THEFIREPLACE, READ THESE INSTRUCTIONS THROUGH,COMPLETELY.i This DESA fireplace and its components are safewhen installed according to this installation manual.Unless you use DESA components, which has beendesigned and tested for the fireplace system, you maycause a fire hazard.i The DESA warranty will be voided by and DESAdisclaims any responsibility for the following actions:a) Modification of the fireplace, components, doors,blower, fans, air inlet system and damper control.b) Use of any component part not manufactured orapproved by DESA in combination with a DESAfireplace system.PROPER INSTALLATION is the most important step inensuring safe and continuous operation of the fireplace.Consult the local building codes as to the particularrequirements concerned with the installation of all factorybuilt fireplaces. Although grounding may not be required bycode the manufacturer recommends it.USE SOLID WOOD OR PROCESSED SOLID FUELFIRELOGS ONLY.This fireplace is not intended to be used as a substitute fora furnace to heat an entire home. Use for supplementalheat only.SELECTING LOCATIONTo determine the safest and most efficient location for thefireplace, you must take into consideration the followingguidelines:1.) The location must allow for proper clearances (seefigures 1 & 2).2.) Consider a location were the fireplace would not beaffected by drafts, air conditioning ducts, windows ordoors.3.) A location that avoids the cutting of joists or roofrafters will make installation easier.4.) An outside air kit is available with this fireplace. Formore details refer to section on outside air kitinstallation on page 3.MINIMUM CLEARANCES TO COMBUSTIBLESx Back and side of fireplace -------------- ¾” minimumNote: The ¾” clearance is not required at the nailing flangesx Floor* ------------------------------------- 0” minimum*See step 2 of “Installing the Fireplace” on page 3x Perpendicular Wall to Opening of unit - 12” minimumx Top Spacers ------------------------------ 0” minimumx Mantel Clearances ---------------------- see page 8“Mantels”x Chimney Outer Pipe Surfaces --------- 2” minimumMINIMUM / MAXIMUM CHIMNEY HEIGHTThe minimum height of the chimney, measured from the baseof the fireplace to the flue gas outlet of the termination, is 14.5feet for straight flue or a flue with one elbow set. Themaximum distance between elbows is 6 feet. For systemswith two elbow sets, the minimum height is 22 feet. Themaximum height of any system is 50 feet. This measurementincludes the fireplace, chimney sections and the height of thetermination assembly at the level of the flue gas outlet (seepage 7, figure 15).FOR YOUR SAFETYx Do not store or use gasoline or any other flammablevapors or liquids in the vicinity of this or any otherappliance.x Due to high temperatures, the appliance should belocated out of traffic and away from furniture anddraperies.x Do not place clothing or other flammable materials onor near the appliance.x NEVER leave children unattended when a fire isburning in the fireplace.WARNING: Improper installation, adjustment,alteration, service or maintenance can cause injury,property damage, or loss of life. Refer to this manual forassistance or additional information. Consult a qualifiedinstaller or local distributor.CHECK LOCAL CODES BEFOREINSTALLING THIS FIREPLACE.WARNING: Do not install a fireplace insert in thisbox unless the manufacturers instructions with the insertspecifically state this fireplace has been tested for usewith the insert.This wood burning fireplace complies with UL 127-CAN/ULS-S610-M87 standard as a FACTORY BUILTFIREPLACE.WARNING: Do not pack required air spaces withinsulation or other materials.FOR CANADA: The authority having jurisdiction (suchas the municipal building department, fire department,etc.) should be contacted before installation to determinethe need to obtain a permit.WARNING: When processed wood fuel fire logsare used, do not poke or stir the logs while they areburning. Use only fire logs that have been evaluated forthe application in fireplace and refer to fire log warningsand caution markings on packaging prior to use.