www.desatech.com56131H 70"36"2"Wall In Front Of Glass36" Min.PerpendicularWall 2" Min.From OpeningRight SideSurround(0" Min.)Left SideSurround(0" Min.)TOP VIEWFigure 6 - Mantel Clearances forPeninsula and See-Thru Fireplaces(Peninsula Shown)21" Min.15" Min.12" Min.4"Min.7" Min.1 1 /2 " Max.UNITSpacer.x.4Combustible.Material.May.Be.UsedDrywall.(Gypsum.Board, Sheetrock, etc.)Safe.Zone.for.Projection.of.Combustible.MaterialWoodwork, such as wood trims, mantels andother. combustible. materials. should. not. be.placed within 7" of the opening of fireplace(see.Figure.6).Combustible.material.above.projecting.more.than. 1. 1/". from. appliance’s. front. face. must.not. be. placed. less. than. 15". from. opening.of appliance, (ref. NFPA Standard 211 Sec.7-3.3.3)PRE-INSTALLATION PREPARATIONContinuedFigure 5 - Minimum Clearances(See-Thru Shown)Combustible.Material Drywall.x.4.StudMinimum.1".Clearance.from.Side.(Only.for.See-Thru)FRAMINGOnce final location has been determined,observing clearances for vent termination,you.may.construct.framing.using.dimensions.shown.in.Figures.7.thru.13.depending.on.your.particular.installation.If.appliance.is.to.be.installed.directly.on.car-peting, tile (other than ceramic), or any com-bustible material other than wood flooring, theappliance.must.be.installed.upon.a.metal.or.wood.panel.extending.the.full.width.and.depth.of. the. appliance.. There. are. three. holes. on.each.side.of.the.bottom.of.unit.where.screws.can be used to secure unit to floor.Figure 7 - Rough Opening for InstallingPeninsula Fireplace39 3 /4 " Min.40 1 / 2"23 5 / 8"39 3 /4 "Min.40 1 / 2"23 5 / 8"*Figure 8 - Rough Opening for InstallingPeninsula Fireplace on Platform* As required by design as long asceiling.clearance.is.maintained.Platform.Must.Be.Solid, Flat,and.Fully.Supported