DESMI PUMPING TECHNOLOGY A/S P a g e | - 86 -Tagholm 19400 Nørresundby - DenmarkPhone.: +45 96 32 81 11Fax : +45 98 17 54 99E-mail: desmi@desmi.comwww.desmi.com26.2.2 ED PumpsWhen mounting a PT100 sensor on an ED pump, apply a small amount of heating conductivepaste on the tip of the sensor, to ensure good heat transfer from the canister that surrounds themedia in the pump and the sensor.Mount the counter nut and turn it as far backwards as possible. Mount the PT100 sensor on thepump rear cover. Turn the sensor in until it touches the canister, when the sensor tip touchesthe canister turn it ¼ revolution back and tighten the counter nut.26.2.3 Bypass valveWhen mounting a PT100 sensor on a bypass valve, the sensor is to be mounted in a sensorpocket. The sensor pocket is always mounted on the bypass valve pressure side, marked “P”.Apply a small amount of heating conductive paste on the tip of the sensor, to ensure goodheating transfer between the sensor pocket and the sensor. The counter nut is turned as farbackwards as possible, and the sensor is mounted in the sensor pocket. Turn the sensor in thesensor pocket until the tip of the sensor touches the bottom, then turn it ¼ revolution back andtighten the counter nut.27. Service centres – DenmarkService center - DenmarkCity Address Telephone FaxNøresundby Tagholm 19400 Nørresundby+45 70236363 +45 9817 5499Kolding Albuen 18 CDK-6000 Kolding+45 70236363 +45 75 58 34 65Aarhus Lilleringvej 20DK-8462 Harlev J+45 70236363 +49 407 522040Hvidovre Stamholmen 173DK-2650 Hvidovre+45 70236363 +45 3677 3399Odense Hestehaven 61DK-5260 Odense S+45 70236363 +45 6595 7565