______________________________________________________________________________DESMI Pumping Technology A/S 5Tagholm 19400 Nørresundby – DenmarkTel: +45 96 32 81 11 Fax: +45 98 17 54 99E-mail: desmi@desmi.comwww.desmi.comPump ØPressurebranchFvNFhNΣ FNΣ MtNmH-40-160 40 1350 1000 1700 220H-50-160 50 1350 1000 1700 220H-50-200 50 1350 1000 1700 200H-65-160 65 1450 1050 1800 270H-65-200 65 1450 1050 1800 270H-80-200 80 1800 1250 2200 470In connection with the permissible loads on the flanges the following is to be observed:vFzinFzoutF 32hFF youtF xoutF yinF xin 2222tMM ZoutM youtM xoutM zinM yinM xin 222222222tMcalcMFcalcFwhere indices "in" is suction branch, "out" is pressure branch, and "calc" are the valuescalculated by the user.3. INSTALLATION3.1 MOUNTING/FASTENINGThe pump should be mounted and fastened on a solid base plate with a flat and horizontalsurface to avoid distortion.The max. permissible loads on the flanges stated in paragraph 2.2 are to be observed.When mounting a V-belt pulley on the pump a bore H7 is recommended. To facilitate themounting the hub in the V-belt pulley may be heated to abt. 100°C after which the V-beltpulley is easily lead over the shaft towards the shoulder. Alternatively, a V-belt pulley may bemounted with a TAPER LOCK bush.When dimensioning the V-belt pulley it is important to follow the rules of the DESMInomograms for the pump size in question - contact DESMI.If the pump is to be driven by a motor via a flexible coupling, motor and pump are to be placed