DuraComm RLP-2024-BBSCLVD Owner's Manual
1RLP-‐2024-‐BBSCLVDHeavy Duty AC to DC Power SupplyOwners Guide(These instructions are intended for use by a technician familiar with electronic products)• Power Factor Correction• Selectable Input Voltage 110 or 220 VAC• Metering: Voltage / Amperage• Remote control / Remote Sense• DC-‐OK TTL signal• Short Circuit / Overload / Over Voltage / Over TemperatureProtection• Manual Battery Disconnect Switch “NEW”• RLP-‐2024BBSCLVD is a continuous duty 28.0 VDC outputpower supply• 3 year warrantyDESCRIPTIONThe RLP-2024-BBSCLVD is a Heavy Duty AC to DC Power Supply. All of the RLP-BBSCLVD comes with a power factorcorrection with metering voltage and amperage. All of the RLP-BBSCLVD come with three layers of protection against overload, overvoltage, over temperature, and short circuit protection. This model also comes with a new manual battery disconnect switch and remotecontrol with remote sense.SPECIFICATIONSOutput Voltage..............................................................................................................................................................................28.0 VOutput Voltage Tolerance............................................................................................................................................................+/- 1 %Output Amperage ........................................................................................................................................................... 17 Amps, cont.Maximum Power, continuous ................................................................................................................................................. 500 WattsMaximum Ripple and Noise..........................................................................................................................................150 mV p-p maxInput Voltage, switch selectable ................................................................................................................................... 110 or 220 VACInput Frequency Range ........................................................................................................................................................... 47-63 HzMaximum AC Current ....................................................................................................................7 Amps/120 VAC; 4 Amps/240 VACTypical Efficiency ............................................................................................................................................................................ 84 %Max Inrush Current, single cycle .............................................................................................................................................. 35 AmpsShort Circuit Protection..............................................................................................................................................Fold Back LimitingOverload Protection (operates) ................................................................................................................................. typical 110-120 %Line Regulation.............................................................................................................................................................................50 mVLoad Regulation .............................................................................................................................................. 100 mV (20-100 % load)Fan Control .................................................................................................................................... Heat sink temp >140 F (60 C) = ONOver Temperature ........................................................................................................................ >195 F (90 C) auto output shutdownRise Time following ON ................................................................................................................................................................50 mSHold Time following OFF ..............................................................................................................................................................10 mSWorking Temperature Range ............................................................................................................................................... -20 -+ 60 CStorage Temperature ...................................................................................................................................... -40 - 185 F (-40 - +85 C)Withstand Voltage* ................................................................................................................. 1.5 KV @ 10 ma (I/P-O/P, I/P-FG)/1 min(Continued) ............................................................................................................................. 500 V @ 10 ma (O/P-FG)/1 minDimensions ......................................................................................................................................3.5H x 19W x 13D inches, nominal |
Related manuals for DuraComm RLP-2024-BBSCLVD
DuraComm RLP-2024BBSCLVD-MU User Manual
DuraComm LP-14 Owner's Manual
DuraComm LP-10 Owner's Manual
DuraComm LP-14N Owner's Manual
DuraComm HE1U-1248-BBLVD Owner's Manual
DuraComm RU1-4012 Owner's Manual
DuraComm RMF-4012 Owner's Manual
DuraComm LPB-12 Owner's Manual
DuraComm LPB-12H Owner's Manual
DuraComm LPX Series Owner's Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine