DuraComm RMF-4012 Owner's Manual
Contents |
` 1 of 3 October 15, 2015RMF‐4012AC to DC Power SupplyOwners Guide(These instructions are intended for use by a technician familiar with electronic products) Auto range voltage input 85 to 264 VAC, 47 to 63 Hz or 120to 370 VDC Available in 12, 24, 48 VDC output (adjustable) Built‐in TTL remote control / remote sense DC‐OK TTL signal Short circuit / over load / over voltage / over temperatureprotections 3 year warrantyDESCRIPTIONThe RMF-4012 has an auto range voltage input of 85 to 264 VAC, with 47 to 63 Hz or 120 to 370 VDC. This unit comes withthree available outputs that are adjustable; these outputs are available in 12, 24, and 48 VDC. All RMF devices have a built-in TTLremote control and remote sense along with a DC-OK TTL signal, along with short circuit, over load, over voltage, over temperatureprotections, and hold UL, CE, TUV, CUL approvals. To guarantee DuraComm’s durability DuraComm offers a 3 year warranty for all oftheir RMF series products.SPECIFICATIONSOutput Voltage .......................................................................................................................................................................13.8 VDCOutput Adjustment Range ............................................................................................................................................. 11 to 14.5 VDCOutput Voltage Tolerance ........................................................................................................................................................ +/- 1 pctOutput amperage, max continuous ......................................................................................................................................... 45 AmpsMaximum Power, continuous ................................................................................................................................................ 600 WattsMaximum ripple and noise .......................................................................................................................................... 120 mV p-p maxInput voltage range (auto-ranging) ..................................................................................................................................... 85-264 VACInput frequency range .............................................................................................................................................................47-63 HzMaximum AC current................................................................................................................. 8.5 Amps/115 VAC; 5 Amps/230 VACTypical Efficiency .......................................................................................................................................................................... 88 %Max inrush current, single cycle ...................................................................................... 35 Amps @ 115 VAC, 70 Amps @ 230 VACOverload Protection (operates) ............................................. typical 85 to 115 %, Constant Current Limiting, Recovers AutomaticallyLine Regulation ............................................................................................................................................................................ 0.3 %Load Regulation ........................................................................................................................................................................... 0.5 %Fan Control ........................................................................................................................ LOAD 35+/-15% or RTH2>/=50 C, Fan OnOver Temperature ....................... +80 C Power Transistor or +100 C Output Choke, Shutdown Output Voltage, Automatic RecoveryRise Time following ON (Full Load) ............................................................................................................................................. 50 mSHold Time following OFF (Full Load) ............................................................................................................................................ 16mSWorking Temperature range ................................................................................................................... -40 to 158 F (-40 C to +70 C)Storage Temperature .............................................................................................................................. -40 C to 185 F (-40 to +85 C)Withstand Voltage ...................................................................................................................................... 3 KVAC @ 10 ma (I/P-O/P)(Continued) ................................................................................................................................... 2 KVAC @ 10 ma (I/P-F/G)(Continued) ..................................................................................................................................500 VAC @ 10 ma (O/P-FG)Dimensions ................................................................................................................................. 3.5H x 19W x 5.25D inches, nominalWeight ............................................................................................................................................................................. 7 lbs, nominalINSTALLATION WARNINGE172782LEVELS |
Related manuals for DuraComm RMF-4012
DuraComm RU1-4012 Owner's Manual
DuraComm LPB-12 Owner's Manual
DuraComm LP-10 Owner's Manual
DuraComm LP-14 Owner's Manual
DuraComm HE1U-5012-MU Owner's Manual
DuraComm LP-14N Owner's Manual
DuraComm LPB-12H Owner's Manual
DuraComm LPX Series Owner's Manual
DuraComm PSRM-5012NFPMU Owner's Manual
DuraComm RLP-2024-BBSCLVD Owner's Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine