Dyson AirbladeTM hand dryer8Connecting to theElectrical SupplyCAUTION: Risk of electricshock! Do not removecasing or attempt repairunless unit is beingserviced by qualifiedservice personnel.If casing is removed orhandled improperly theinternal components ofthe Dyson AirbladeTM maycause harm or becomepermanently damaged.Connect to the electrical supplyusing approved flexible or solidconduit and electrical fittings.Ensure that the flexible or solidconduit and the electrical cableis of sufficient length to makethe necessary connection tothe backplate and that sufficientlength to reach the terminal block.Step 1.Using a flat-head screwdriver, prythe appropriate metal knock-outfrom backplate in one of thelocations pictured in Fig 7.Step 2.Install electrical entrance fittinginto knock-out.If mounting in knock-out 1:Lay the unit flat on its back.Remove the T-25 Torx screw at thebottom of the PCB housing, tilt thePCB housing up and pulldownward as illustrated in Fig 8.Pull outward of gasket and turn thePCB Housing clockwise and set offto the side. Route the incomingsupply wires to the terminal blockand secure them into the properlocations as illustrated in Fig 9.Installation ProceduresView from BackReconnect the PCB Housing in theopposite order as it was removed.Proceed to step 3.If mounting in knock-out 2:Route the incoming supply wiresto the terminal block and securethem into the proper locationsas illustrated in Fig 9.Fig 8Fig 7Knock-outs2 1ENGknock‑outs