Eaton ATC-100 Instructional Booklet
Also see for ATC-100: Instructional bookletOperation & maintenance manual
Instructional BookletPage 14 Effective: March 2010O&M Manual for the Eaton ATC-100Automatic Transfer Switch ControllerFor more information visit: www.eaton.com IB01602019ESection 5: Troubleshooting and Maintenance5.1 Level of RepairThis manual is written with the assumption that only ATS trouble-shooting will be performed. If the cause of malfunction is tracedto an ATC-100, the unit should be replaced with a new unit. Themalfunctioning unit should then be returned to Eaton Electrical,Inc. for factory repairs.5.2 ATC-100 TroubleshootingThe Troubleshooting Guide (Table 3) is intended for service per-sonnel to identify whether a problem being observed is external orinternal to the unit. For assistance with this determination, con-tact Eaton Electrical. If a problem is identified to be internal, theunit should be returned to the factory for replacement.Table 3. Troubleshooting Guide.SYMPTOM PROBABLE CAUSE POSSIBLE SOLUTION(S)All front panel LED’s are off. Control power is deficient or absent.ATC-100 is malfunctioning.Verify that control power is connected at J7 and that it is withinspecifications.Replace the unit.“Unit Status” LED is not blinking. Control power is deficient or absent.ATC-100 is malfunctioning.Verify that control power is connected at J7 and that it is withinspecifications.Replace the unit.Front panel pushbuttons do not work. Bad connection inside the ATC-100. Replace the unit.Utility source or Generator source is not availablewhen it should be.Voltage and/or frequency are not within set-point values. Verify voltage and/or frequency with multimeter. Check the pro-grammed setpoint values.“Utility Connected” LED is blinking. Utility switching device did not open when it was commanded to open(within 6 seconds).Utility switching device did not close when it was commanded to close(within 6 seconds).Utility closed contacts did not open when Utility switching device opened(within 6 seconds)Utility closed contacts did not close when Utility switching device closed(within 6 seconds).Check the utility circuit breaker shunt trip (ST) wiring.Check the utility circuit breaker spring release (SR) wiring.Check the utility closed control input wiring on J-4, Pins 1 and 2.Check the utility closed control input wiring on J-4, Pins 1 and 2.Press Reset pushbutton on rear of unit to reset the fault.“Generator Connected” LED is blinking. Generator switching device did not open when it was commanded to open(within 6 seconds).Generator switching device did not close when it was commanded toclose (within 6 seconds).Generator closed contacts did not open when Generator switching deviceopened (within 6 seconds).Generator closed contacts did not close when Generator switching deviceclosed (within 6 seconds).Check the generator circuit breaker shunt trip (ST) wiring.Check the generator circuit breaker spring release (SR) wiring.Check the generator closed control input wiring on J-4, Pins 1 and 3.Check the generator closed control input wiring on J-4, Pins 1 and 3.Press Reset pushbutton on rear of unit to reset the fault.“Generator Available” LED is blinking. Generator source voltage and/or frequency were not within setpoint val-ues within 90 seconds of trying to execute a System Test, Engine Start,or Generator Test.Verify generator voltage and/or frequency with multimeter. Checkthe engine maintenance.Press Reset pushbutton on rear of unit to reset the fault.Unit will not perform an Engine Start test. Engine Start pushbutton was not pressed.Generator source voltage and/or frequency did not become availablewithin 90 seconds of engine starting.Press and hold (for 5 seconds) the Engine Start pushbutton to ini-tiate the test.Verify the voltage and/or frequency with a multimeter. Check theengine maintenance.Unit will not perform a System Test. System Test pushbuttons were not pressed.Generator source became unavailable when connected to the load.Generator source became unavailable before connecting to the load.Generator source voltage and/or frequency did not become availablewithin 90 seconds of engine starting.Simultaneously press the Engine Start and Set Generator Test push-buttons to initiate the test.Check the generator/load sizing.Check the generator for proper function.Verify the voltage and/or frequency with a multimeter. Check theengine maintenance.Generator Test failed to exercise. Generator source voltage and/or frequency did not become availablewithin 90 seconds of engine starting.Generator source became unavailable when connected to the load.Generator source became unavailable before connecting to the load.Verify the voltage and/or frequency with a multimeter. Check theengine maintenance.Check generator/load sizing.Check the generator for proper function.Engine fails to start after the TDES timer times out. Incorrect wiring.Generator Start relay Normally Open contacts are not closed.Engine did not start.Check the wiring between the Generator Start relay (J-5) and theengine.Replace the unit.Check the generator for proper function. |
Related manuals for Eaton ATC-100
Eaton ATC-100 Instructional Booklet
Eaton ATC-300 Instruction Booklet
Eaton ATC-900 Instruction Booklet
Eaton RLC1 Instructional Booklet
Eaton RTC-50 Instruction Booklet
Eaton EGS Series Instruction Booklet
Eaton EGS Series Instruction Booklet
Eaton Magnum DS Instruction Booklet
Eaton EGS Series Instruction Booklet
Eaton 10250T Instructional Leaflet
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine