6BLK Super LED Technical M anualBLK SUPER LED TECHNICAL MANUAL TMF0071.A www.eaton.comTechnical DataCasing Seawater-resistant aluminium (ABS), Surface: epoxy resin-coated, colour: grey / blackHood Polycarbonate; Colours: glass-clear, red, yellow, green, blueInsulation class IProtection type IP 65Cable gland 1x M20 x 1.5 for cables 8-12 mmTemperature rangeOperation (Ta)Storage see table on page 2-60°C to +80°COperating position any, preferably wall mounted (cable entry downward) / ceiling mountedOperating conditions indoor or outdoorTerminals terminal capacity: max. 2.5 mm2Weight approx. 1.4 kgOperating modes:Pos. 0Pos. 1Pos. 2Continuously onFlashing 0.5 s on, 0.5 s offStrobe sequence 7x each: 55 ms on, 19 ms off, 1s pause, then sequence repeatsUser information1. The appliance has been designed for insulation class I and is only to be connected to, and operated with, thespecified voltage. Specifications of polarity must be observed. Ensure that the ground wire is correctly connected.2. Ensure that the casing is not damaged.3. The relevant codes of Practice an Trade Association requirements for save operation must be observed.4. Live components may be come exposed when covers are opened or parts are removed. Before opening theappliance for alignment, maintenance, repair or replacement of parts, the appliance must be disconnected from allpower supplies. If it is necessary to carry out alignment, maintenance or repair on the open and live device, this isonly to be undertaken by a qualified specialist who has received corresponding instruction.5. Capacitors may still be in a charged state even after the appliance has been disconnected from all power supplies.6. The appliance is only to be operated under the specified ambient conditions and in the specified mode of operation.Unfavourable ambient conditions may cause damage to the appliance and put the user’s life at risk. Unfavourableambient conditions may be:• excessive air humidity (> 95%, relative, condensing)• moisture, dust (observe protection class)• flammable gases, vapours, solvents• excessively high ambient temperatures (>+70°C)7. The pressure compensating valve fitted on the base of the casing must not be covered.8. The ambient temperatures must be within the specified range.9. The appliance is designed for both indoor and outdoor use.10. The installation and commissioning of the appliance may only be carried out by a qualified specialist; the sameapplies to any repairs with original spare parts. The use of other than original spare parts may cause damage or injury.11. The appliance has a very intense lighting strength. In order to avoid damage to eyesight, please refrain from lookingat the lamp for any length of time when it is in operation.Subject to alterations or errors