Eaton C440 Installation Leaflet
2Installation Leaflet IL04209006EEffective July 2010PROFIBUS Module for use withMotor Insight, C440 and S611EATON CORPORATION www.eaton.comSpecification ValueNumber of Inputs 4Nominal Voltage 24 VdcNominal Current 5mAType Current SinkingInput Type IEC 61131-2, Type 1 DigitalMax 24 Vdc Source Current 50mAPROFIBUS Adapter Setup and ConfigurationConfigure C441 Profibus Adapter1. Load the gsd file for the C441 Profibus Adapter into the Master’sconfiguration tool.2. Select and add the C441 Profibus Adapter to the networkconfiguration.3. The default configuration for the C441 Profibus Adapter is aStandAlone IO base. If the C441 Profibus Adapter is to connectto a base device; remove the modules from all 28 slots of thedefault configuration.4. Select and add the attached device’s base moduleto slot 1 of the C441 Profibus Adapter configuration.NOTE: The appropriate base module MUST be placed in slot 1 ofthe configuration. Failure to do so will cause configuration to fail.5. Select and add the desired modules for the data exchange intoslots 2 - 28. Select only those modules supported by the basemodule (See the base device’s user manual for a list of sup-ported modules)Example Configuration:I/O module Type DescriptionC441 MotorInsight Base base - no IO Attached DeviceCom Adapter Outputs output - 1 byte Controls C441 adapteroutputsMI Command Register output - 2 bytes Controls MI Relay-start/stopCom Adapter Inputs input - 1 byte Status of C441 adapt-er inputsMI RMS Current Ave input - 2 bytes Average rms currentreadingMI RMS Voltage Ave input - 2 bytes Average rms voltagereadingMI Total Kilowatts input - 2 bytes Total power readingSetup C441 Profibus Adapter Device Parameters1. Select the C441 Profibus Adapter to display its device param-eters.2. Set the “Enable Device Parameters & Adapter Outputs ComLosBehavior” parameters.Note: To enable writing of the device parameters into the attachedbase device “Enable Device Parameters” must be set to “DownloadDevice Parameters”.Setup the Device Parameters1. Select the base module in the configuration to display its deviceparameters. The base module contains the parameters to en-able/disable faults, set thresholds, etc. for the attached device.Example: The following parameters can be found in C441MotorInsight Base Module• CT Multiplier• Overload FLA• Overload Trip Class• GND Fault Trip Level• Low KW Trip Level• High KW Trip Level• Under Voltage Trip Level• Over Voltage Trip LevelAfter all configuration is complete, save and download the newconfiguration settings to the Master(PLC) & C441 ProfibusAdapter.Profibus DiagnosticsThe C441 Profibus Adapter provides the user with status informationalong with fault and warning data relevant to the operation of theattached base module. Fault and warning information is presented tothe user through extended diagnostics. All fault information is sentto the Master as high priority diagnostic messages (ext. diag. bit setin diagnostic message). All warning information is sent as low prior-ity diagnostic messages (ext diag. bit clear). Low priority diagnosticmessages are issued as the fault condition clears.See the User Manual for the attached base module’s diagnostic mes-sage bit definitionsEnvironmental Ratings of the ModuleTransportationand StorageTemperature -40ºC to 85ºC (-40ºF to 185ºF)Humidity 5 - 95 % non-condensingOperatingTemperature -20ºC to 50ºC (-4ºF to 122ºF)Humidity 5 - 95 % non-condensingAltitude Above 2000meters (6600feet)consult factoryShockICE 60068-2-2715G any direction for11 millisecondsVibrationIEC 60068-2-63G in any directionPolution Degree 3 |
Related manuals for Eaton C440
Eaton Power Xpert C445B Series Installation Leaflet
Eaton PM3 Instruction Leaflet
Eaton PKE-SWD-CP Instruction Leaflet
Eaton MMX-COM-PC Instruction Leaflet
Eaton KES 310+ Instruction Leaflet
Eaton PXR-PCAM Instruction Leaflet
Eaton PKE-COM-RTU Instruction Leaflet
Eaton MSFI-80A Instruction Leaflet
Eaton XIOC-SER Instruction Leaflet
Eaton NZM2-XMVR Instruction Leaflet
manualsdatabase
Your AI-powered manual search engine