Eaton Cautiex D4-S5 Installation And Operating Manual
EatonCooper Sécurité SASPEE II - Rue Beethoven - BP1018463204 RIOM CEDEX FRANCETél. +33 (0)825 826 212(0,15 € TTC/min)www.cooperfrance.comwww.eaton.eu© 2015 EatonZNO1031000 B - 09/2015Tous droits réservés.All Rights Reserved.Eaton est une marque déposée.Eaton is a registered trademark.Toutes les autres marques appartiennent à leurspropriétaires respectifs.All trademarks are propertyof their respective owners. Smoke Alarm09/2015 NUG35940Installation and Operating ManualZNO1031000 BThis self-contained smoke alarm is suitable for:• individual houses and flats;• camper-vans and caravans.WARNINGNOT SUITABLE FOR BOATS.Read this manual carefully before use and keep it for anyfuture use.1. MountingDo not paint the smoke alarm.The device should be ceiling-mounted, in a place where it is easy to accessto facilitate tests and cleansing.The smoke alarm must be placed at min. 50 cmfrom closest wall and at max. 10 m from otheralarm, preferably in the middle of the ceiling.Location• Minimum one alarm between poten-tial sources of fire and bedrooms.• One optional alarm on each floor, incorridors and staircases.• One optional alarm in each living area,bedrooms, living-room - dining room,storerooms.Do not place any smoke alarm:• in dusty rooms;• on top of a steep roof or in a blind angle;• in rooms where temperature can go either below +4ºC or above +38ºC;• in rooms where non-condensing relative humidity can be more than90%;• in kitchens, garages, rooms with fireplaces where humidity and smokeare frequent.Smoke alarm mounting1. Unclip the alarm from its base turningcounterclockwise.2. Use the base to mark fixing holes with a pencil onthe ceiling. Then fix the base to the ceiling usingprovided screws and wall plugs.3. Remove transparent insulating label from the battery.Note: The alarm cannot be mounted onto the base ifthe battery is not installed.4. After installation, press Test button totest the alarm. The device will make ahigh pitched and loud sound.IMPORTANT : Do not remove productinternal label. It shows important informationrelative to the device.2. OperationNormal mode LED flashing approximately every 48 seconds without sound.Alarm mode LED flashing + high pitched loud discontinuous sound every second.Low battery Short sound + LED flashing every 48 seconds.To be replaced within 30 days.Hush FunctionIn case of false alarm, press Hush button while the alarm is on to cut it off.Alarm mode will come back after about 10 minutes.3. TestTest the smoke alarm at first use, once a month, and after every batteryreplacement pressing Test button.• Operation OK: short high pitched and loud sound + LED flash.4. Technical featuresAlarm Lithium battery (included)Type Photoelectric non-radioactive Type 3 V CR2 Desay/DuracellreplaceableSignal Repeated high pitchedsounds (in case of fire) WARNINGGOOD OPERATION OF THE DETECTORIS ENSURED BY DESAY/DURACELLBATTERY USE.Level Min. 85 dB at 3 m5. MaintenanceMonthly clean-up: dusting with vacuum cleaner and optional wiping with awet cloth.Do not open the alarm.Problem Cause SolutionFalse alarm Dust particles in thechamber filterorHigh condensinghumidityHeavily blow on themesh or vacuum with avacuum cleaner.Dry the alarm.No sound when Testbutton is pressed Battery is probably low. Replace the battery.Replace the smoke alarm every 10 years or if alarm isdamaged.6. RecyclingBattery and smoke alarm need a specific treatment. Follow local regulationsand laws relative to recycling.7. Essential certified characteristics covered by the NFType of mounting Ceiling onlyMain power supply Internal power supplyBattery duration 5 yearsInterconnectable device NoSuitable for installation in camper-vans YesConnection to external auxiliary devices NoRadio link NoIndividual alarm indicator YesAlarm silence facility (10 minutes) YesAccessibility Option NoSoundChamberfilterTest/Hushbutton / LEDMountingbase5 year Smoke Alarm diameter 4cmD4-S5bathroomoptional alarmsminimum alarmsbedroombedroom corridorliving-roombasementkitchenbedroom1550 cm min.CeilingWallGeneral warranty termsCOOPER SÉCURITÉ SAS (Groupe EATON) warranties these products for a 1-year period (date ofmanufacture as proof), under the general terms set out below.• Full warranty on parts and workmanship.• Any defective luminaires shall be returned carriage paid toCOOPER SÉCURITÉ SAS (Groupe EATON) Parc Européen d’Entreprises II, Rue Beethoven, BP 10184,63204 RIOM Cedex, FRANCE.Self-contained luminaires replaced or repaired under the terms of this warranty shall be shipped backcarriage paid.The warranty is void:• if the material has been transformed, modified or repaired outside of COOPER SÉCURITÉ SAS(Groupe EATON) workshops;• if the defectiveness is due to misuse or inappropriate connection.0333The CE marking on this product is securing the conformity to the European directives that are applicableand in conformity to the harmonised specification of EN 14604.NF – DOMESTIC FIRE SAFETY brand is testing the conformity of this product to the certification NF 292.DAAFPARAFNORCERTIFICATIONwww.marque-nf.comEN14604 : 2005 + AC : 2008DoP No. 2001-0270333-CPR-292051-15AFNOR Certification - 11 rue Francis de PressenséFR - 93571 LA PLAINE SAINT DENIS Cedex FRANCE |
Related manuals for Eaton Cautiex D4-S5
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine