Eaton ELC-AN04ANNN Instruction Sheet
Also see for ELC-AN04ANNN: Basic training manual
IL05003002E.pdf5011629803-AN032007-05-08ELC-AN04ANNNAnalog to Digital Converter ModuleInstruction SheetWARNING• This Instruction Sheet only provides descriptions for electrical specifications, generalspecifications, installation & wiring, troubleshooting and peripherals. For more information aboutthe optional peripherals, please see ELC Application Manual.• This is an OPEN TYPE Controller. The ELC should be kept in an enclosure away from airbornedust, humidity, electric shock risk and vibration. Also, it is equipped with protective methodssuch as some special tools or keys to open the enclosure, so as to avoid the hazard to usersand the damage to the ELC. Do NOT touch terminals when power on.• Never connect the AC main circuit power supply to any of the input/output terminals, as it willdamage the ELC. Check all the wiring prior to power up. To avoid any electromagnetic noise,make sure the ELC is properly grounded .• Warning – Do not disconnect while circuit is live unless area is known to be non-hazardous.• Power, input and output (I/O) wiring must be in accordance with Class 1, Div. 2 wiring methods -Article 501-10(B)(1) of the National Electrical Code.• Suitable for use in Class 1, Division 2, Groups A, B, C, D or Non-Hazardous locations only.• Warning – Explosion hazard - Substitution of components may impair suitability for Class 1,Division 2.• Warning – Explosion Hazard - Do not disconnect equipment unless power has been switchedoff or the area is known to be Non-Hazardous.1 INTRODUCTION1.1 Model Explanation and PeripheralsThank you for choosing Eaton Logic Controller (ELC) series products. The analog input modulereceives external 4-point analog signal input (voltage or current) and transforms it into 14 bits digitalsignal. The analog input module of ELC-AN04ANNN can read/write the data of analog input moduleby using commands FROM / TO via ELC program. There are 49 CR (Control Register) in eachmodule and there are 16 bits in each register.1.2 Product Profile and Outline1213 1411MCH3CH1CH2MMEXTENSIONPORT13235 6 87489106090ELC-AN04ANNN3CH4M25.23Units: mm1. Status indicator (Power, RUN and ERROR) 2. Model Name3. Extension unit clip 4. Input/output terminal5. DIN rail clip 6. Mounting hole of the extension unit7. Nameplate 8. Extension unit clip9. DIN rail (35mm) 10. Extension port11. RS-485 Communication port 12. 2 pin removable terminal (standard accessory)13. DC power input 14. Power input cable (standard accessory)1.3 External wiringVoltage Input-10V ~ +10VCurrent Input-20mA ~ +20mAV+COMIsolation Wire 1¡@** 5@FGI+ 250 Ω~~V+FGI+* 2@CH1CH4250 Ω24+24-* 3@AG+15V-15VDC/DCConverter* 4@SystemGroundingClass 3 Grounding(100 or less)ΩCOMCH1CH4104.7K104.7KAG104.7K104.7KAGIsolation Wire 1¡@*terminal ofpower moduleWarning: DO NOT wire to the No function terminal. UseCopper Conductor Only, 60/75 °C.Note 1: Please isolate analog input andother power wiring.Note 2: If connect to current signal,please short circuit between V+ and I+terminals.Note 3: If noise is too loud, pleaseconnect FG to grounding.Note 4: Please connect terminalof power module and terminal ofanalog input module to system earthpoint and make system earth point begrounding or connects to machinecover.Note 5: If wave of input terminal ofloaded is too big that noise interfereswiring, please connect capacitance with0.1~0.47uf 25V.1.4 Terminal of analog module layoutAN04ANNN AN02NANN AN04NANN AN06AANN PT04ANNN TC04ANNNELC-AN04 NA NN●CO MFGCO MFGV+V+I+I+●CO MFGCO MFGV+V+I+I+ELC-AN02NANN●CO MFGCO MFGV+V+I+I+POWERERRORD/ACOMFG●I+COMFGV+COMI+V+●FGV+I+COMV+FGI+ELC-AN04NANNCO MCO MV+V+I+I+ELC-AN06AANNDAER RORPOW ERCO MI+V+CO MCO MV+V+I+I+CO MI+V+I-L +FGL -ELC-PT04ANNN●I-L +FGL -I-L +FGL -●I-L +FGL -SLDL +L -●ELC-TC04ANNNSLDL +L -●●SLDL +L -●SLDL +L -●●2 STANDARD SPECIFICATIONS2.1 Function SpecificationsFOUR CH. A/D MODULE VOLTAGE INPUT CURRENT INPUTPower supply voltage 24 VDC(20.4VDC~28.8VDC) (-15%~+20%)Analog input channel 4 channel / each moduleAnalog input range ±10V ±20 mADigital conversion range ±8,000 ±4,000Resolution 14 bits(1LSB=1.25 mV) 13 bits (1LSB=5μA)Input impedance 200 KΩ and above 250ΩOverall accuracy ±0.5% of full scale at 25℃(77℉)±1% of full scale during 0~55℃ (32~131℉)Response time 3 ms × channelsIsolation method It has isolation between digital area and analog area. There is no isolationamong channels.IsolationField to Digital Area: 500VField to Analog Area: 500VAnalog area to Digital Area: 500VField to 24VDC: 500VAbsolute input range ±15 V ±32 mADigital data format 2’s complementary of 16-bit, 13 Significant BitsAverage function Yes (CR#2~CR#5 can be set and setting range is K1~K100)Self diagnose function Upper and lower bound detection / channelsCommunication mode (RS-485)MODBUS ASCII/RTU Mode. Communication baud rate of 4,800 / 9,600 /19,200 / 38,400 / 57,600 / 115,200 bps. For ASCII mode, date format is7Bits, even, 1 stop bit (7,E,1). For RTU mode, date format is 8Bits, even, 1stop bit (8,E,1). The RS-485 is disabled when the ELC-AN04ANNN isconnected in series to an ELC.Connect to ELC in seriesThe input point of the first analog extension unit it connects from the near tothe distant is from 0 to 7. The Max. is 8 modules and it won’t waste digitalI/O point.Max. rated consuming power 24 VDC(20.4VDC~28.8VDC) ( –15%~+20%), 2W, supply from externalpowerNoise ImmunityESD(IEC 61131-2, IEC 61000-4-2): 8KV Air DischargeEFT(IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV,Analog & Communication I/O: 1KVRS(IEC 61131-2, IEC 61000-4-3): 26MHz~1GHz, 10V/mGroundingThe diameter of the grounding wire cannot be smaller than that of terminals24V and 0V (if numerous ELCs are used at the same time, make sure thateach ELC is grounded respectively to the ground poles)Vibration/Shock Immunity International Standard Regulations: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)Operation/Storage Environment Operation: 0℃~55℃(temperature), 50~95% (humidity), pollution degree: 2;Storage: -25℃~70℃(temperature), 5~95% (humidity)Agency ApprovalsUL508UL1604, Class1,Div2 Operating temperature code: T5European community EMC Directive 89/336/EEC and Low VoltageDirective 73/23/EEC3 CR (CONTROL REGISTER)ELC-AN04ANNN EXPLANATIONCRNo.Comm.address Latched Register name b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0#0 H 4000 O R Model type System used, data length is 8bits (b7~b0).ELC-AN04ANNN model code =H 88#1 H 4001 O R/W Input mode settingReserved CH4 CH3 CH2 CH1Input mode setting: factory setting is H0000.Mode 0: input voltage mode (-10V~+10V).Mode 1: input voltage mode (-6V~+10V).Mode 2: input current mode (-12mA~+20mA)Mode 3: input current mode(-20mA~+20mA)Mode 4: Reserved.#2 H 4002 O R/W CH1 average numberAverage numbers setting of channel CH1~CH4. Setting range is K1~K100and factory setting is K10.#3 H 4003 O R/W CH2 average number#4 H 4004 O R/W CH3 average number#5 H 4005 O R/W CH4 average number#6 H 4006 X R Average value of CH1 inputsignalDisplay average value of CH1~CH4 input signal#7 H 4007 X R Average value of CH2 inputsignal#8 H 4008 X R Average value of CH3 inputsignal#9 H 4009 X R Average value of CH4 inputsignal#10 ~ #11 Reserved#12 H 400C X R Present value of CH1 inputsignal Display present value of CH1~CH4 input signal#14 H 400E X R Present value of CH3 inputsignal Display present value of CH1~CH4 input signal#15 H 400F X R Present value of CH4 inputsignal#16 ~ #17 Reserved#18 H 4012 O R/W To adjust OFFSET value ofCH1Offset setting of CH1~CH4. Factory setting is K0 and unit is LSB.Voltage input: setting range is K-4,000 ~K4,000Current input: setting range is K-4,000 ~K4,000#19 H 4013 O R/W To adjust OFFSET value ofCH2#20 H 4014 O R/W To adjust OFFSET value ofCH3#21 H 4015 O R/W To adjust OFFSET value ofCH4#22 ~ #23 Reserved#24 H 4018 O R/W To adjust GAIN value of CH1 GAIN setting of CH1~CH4. Factory setting is K4,000 and unit is LSB.Voltage input: setting range is K-3,200 ~K16,000.Current input: setting range is K-3,200 ~K10,400.#25 H 4019 O R/W To adjust GAIN value of CH2#26 H 401A O R/W To adjust GAIN value of CH3#27 H 401B O R/W To adjust GAIN value of CH4#28 ~ #29 Reserved#30 H 401E X R Error status It is the data register to save all error status. Please refer to fault code chartfor detail.#31 H 401F O R/W Communication addresssettingSetting RS-485 communication address. Setting range is 01~255 andfactory setting is K1#32 H 4020 O R/W Communication baud ratesettingIt is used to set communication baud rate (4,800, 9,600, 19,200, 38,400,57,600, 115,200bps). Communication format: ASCII mode is 7Bit, even bit, 1stop bit (7,E,1). Communication format of RTU mode is 8Bit, even bit, 1 stopbit (8,E,1).b0: 4,800 bps (bit/sec). b1: 9,600 bps (bit/sec). (factory setting)b2: 19,200 bps (bit/sec). b3: 38,400 bps (bit/sec).b4: 57,600 bps (bit/sec). b5: 115,200 bps (bit/sec).b6~b13: reserved.b14: exchange low and high byte of CRC check code (only for RTU mode)b15: ASCII / RTU mode selection#33 H 4021 O R/WReset to factory setting and setcharacteristics adjustablepriorityb15 b14 B13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0Reserved CH4 CH3 CH2 CH1Output latched setting, factory setting H0000Give CH1 setting for example:1. When b0=0, user can set OFFSET and GAIN value of CH1 (CR#18,CR#24). When b0=1, inhibit user to adjust OFFSET and GAIN value ofCH1 (CR#18, CR#24).2. b1 means if characteristic register is latched. b1=0 (factory setting,latched), b1=1 (not latched).3. When b2 is set to 1, all settings will reset to factory setting. |
Related manuals for Eaton ELC-AN04ANNN
Eaton ELC-MC01 Instruction Sheet
Eaton ELC-MC01 Instruction Sheet
Eaton ELC-CADNET Instruction Sheet
Eaton ELC-COENETM Instruction Sheet
Eaton ELC-EX08NNSN Instruction Sheet
Eaton ELC-PC12NNDR Instruction Sheet
Eaton ELCM Series Instruction Sheet
Eaton ELC-GPXFERMOD Instruction Sheet
Eaton 9376-SP Instruction Sheet
Eaton Crouse-Hinds Series Instruction Sheet
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine