Eaton HMI04BU Quick Start Manual
Also see for HMI04BU: CatalogInstruction leaflet
Quick Start GuideFor HMi Operator InterfaceGeneral DescriptionPositioned between the ELC graphics panels and the ePro series of operator interfaces, HMi is the workhorse of the industry. All units feature a touchscreen and function keys to suit all environments andapplications. They range in screen size and color to fit available space and application needs. All unitsoffer RS-232, RS-485 and RS-422 communications.• True analog touchscreen • Retentive internal data storage• Real time trending • Trend stored data• Alarming and alarm storage • Alarm frequency• Event storage (History) • USB programming• USB memory storage • USB printer• Add I/O • Macro programming• Multi-language • Recipe storage• Auto-scale application from 10 – 4" • On-line simulation• Off-line simulation • 10 level password protectionSafety InformationCarefully note and observe the following safety precautions when receiving, inspecting, installing,operating, maintaining and troubleshooting. The following words, WARNING AND CAUTION, are used tomark safety precautions when using the Eaton product. Failure to observe these precautions may voidthe warranty!Installation• Comply with instructions for installation. Otherwise it may cause equipment damage.• Do not install the product in a location that is outside the stated specification for the device. Failureto observe this caution may result in electric shock, fire or personal injury.Wiring• Connect the ground terminals to a class-3 ground (ground resistance should not exceed 100Ω).Improper grounding may result in electric shock or fire.Operation• HMi users should use screen editor software to perform editing. Using HMi without the screeneditor software may result in abnormal operation.• Do not modify wiring during operation. Otherwise it may result in electric shock or personal injury.• Never use a hard or pointed object to hit or strike the screen as doing this may damage the screen,causing HMi to work abnormally.Maintenance and Inspection• Do not touch any internal or exposed parts of the device as electrical shock may result.• Do not remove operation panel while power is on. Otherwise electrical shock may result.• Wait at least 10 minutes after power has been removed before touching any terminals orperforming any wiring and/or inspection as an electrical charge with hazardous voltages may stillremain in the unit even after power has been removed.• Turn the power off before changing backup battery and check system settings after finishing thechange (all data will be cleared after changing the battery).• Be sure the ventilation holes are not obstructed during operation, or malfunction may result.Wiring Method• Remove the terminal block from the HMi before wiring.• Insert only one wire into one terminal on the terminal block.• If the wiring is in error, perform the wiring again with proper tools. Never use force to remove theterminals or wires, or malfunction or damage may result.Communication Wiring• Comply with communication wiring specification for wiring.• Wiring length should comply with the stated specification for HMi.• Ensure proper grounding to avoid bad communication quality.Available Communication Parts2COM1 PortPIN ContactRS-2321 N.C.2 RXD3 TXD4 N.C.5 GND6 N.C.7 RTS8 CTS9 N.C.A Power input terminalB Expansion slotC Memory cardD COM 2E COM 1F USBA Power input terminalB Expansion slotC Memory cardD COM 2E COM 1F USBA Power input terminalB Expansion slotC Memory cardD COM 2E COM 1F USBG Battery coverCOM2 PortPIN MODE 1 MODE 2RS-422 RS-485R- RXD- D-R+ RXD+ D+T- TXD- D-T+ TXD+ D+G GND GNDCOM2 and COM3 PortCOMMPort PIN MODE 1 MODE 2 MODE 3 MODE 4 MODE 5 MODE 6RS-232 RS-422 RS-485 RS-232*2 RS-422*2 RS-485*2COM21 N.C. RXD- D- N.C. RXD1- D1-2 RXD RXD+ D+ RXD1 RXD1+ D1+3 TXD TXD+ D+ TXD1 TXD1+ D1+4 N.C. TXD- D- N.C. TXD1- D1-5 GND GND GND GND GND GNDCOM36 N.C. RTS- N.C. N.C. TXD2- D2-7 RTS RTS+ N.C. TXD2 TXD2+ D2+8 CTS CTS+ N.C. RXD2 RXD2+ D2+9 N.C. CTS- N.C. N.C. RXD2- D2-COM1 and COM3 PortCOMMPort PIN MODE 1 MODE 2RS-232 RS-422COM11 N.C. N.C.2 RXD RXD13 TXD TXD14 N.C. N.C.5 GND GNDCOM36 N.C. N.C.7 RTS TXD28 CTS RXD29 N.C. N.C.CAD E F BCABDEFGCABDEFG4" HMi6" HMi8" HMi10" HMiHMi OperatorInterfacesAccessories (sold Separately)The following accessories could help improve your HMi experience.• ELC-CBPCELCE — 3 meter cable to connect between the HMi and Eaton Logic Controller (ELC)• ELC-CBPCELC1 — 1 meter cable to connect between the HMi and Eaton Logic Controller (ELC)• HMIECPTR parallel printer expansion module• HMIEC0808 8 input and 8 output expansion module• HMIECENT Ethernet expansion card. Modbus TCP, upload and downloadUnpack and InspectIncluded with the HMi are:• Panel Mounting clips (number of clips varies depending on the size of the unit).• DB9 gender changer for easy connection to the Eaton Logic Controller (ELC).• 3-pin power 24V DC connector.1 For 6", 8" and 10" HMi Only8" HMi10" HMi6" HMiA Power input terminalB COM 2C COM 1D USBA BDC4" HMiFor 4" HMi Only |
Related manuals for Eaton HMI04BU
Eaton XV-102 Series Quick Start Manual
Eaton XP-503 User Manual
Eaton MTL661 Instruction Manual
Eaton XP-503-10-A10-A01-1B Manual
Eaton Cutler-Hammer PanelMate Manual
Eaton XP-702 Series Operating Instructions Manual
Eaton XP-504 Series Instruction Leaflet
Eaton XV-102 Series Instruction Leaflet
Eaton XP-503 Instruction Leaflet
manualsdatabase
Your AI-powered manual search engine