INS #Brand Logoreversed out ofblackINS #IB505051EN 049-304Installation Instructions for the Sure-Lites LPX Combination Exit/Emergency Lightsand Exits with Self DiagnosticsWARNINGRisk of Fire/Electric ShockIf not qualified, consult an electrician.WARNINGRisk of Electric ShockDisconnect power at fuse or circuit breaker beforeinstalling or servicing.Important SafeguardsWHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETYPRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDINGTHE FOLLOWING.1 READ AND FOLLOW ALL SAFETY INSTRUCTIONS2 Do not use outdoors.3 Do not use in hazardous locations, or near gas or electricheaters.4 Do not let power supply cords touch hot surfaces.5 Do not use this equipment for other than the intended use.6 Installation is to be performed only by qualified personnel.7 Install in accordance with National Electric Code and localregulatory agency requirements.8 The use of accessory equipment not recommended by themanufacturer may cause an unsafe condition.9 Equipment should be mounted in locations and at heightswhere it will not readily be subjected to tampering byunauthorized personnel.10 SAVE THESE INSTRUCTIONSMAX MOUNTING HEIGHT:17.24 FTWALL MOUNT INSTALLATION1 Extend unswitched 24 hour AC supply of rated voltage tojunction box (by others). Leave at least 18 inches of slack.Circuit should not be energized at this time.2 Remove the stencil face and lens assembly by applying ascrewdriver to the snaps located at the top and bottom ofthe stencil face.3 Knock out the appropriate mounting pattern and wire passhole to match junction box. Use the integrated wire hookin the backplate to hold the wires in place so that there isno shadowing on the face of the sign (see Figure 1).4 Connect power supply and ground in accordance withlocal codes. Wire connections as follows: 277VAC/240VACline to Orange lead or 120V line to Black lead; Neutral or240V (Common) to white lead (see Schematic). Cap unusedline lead.Note: Connections must be the enclosure rated area of theframe (top left corner) or junction box (see Figure 1).5 Mount to junction box.6 Determine which color sign face is needed. If red isneeded, proceed to step 97 If green is the desired color, remove the red lens fromthe stencil and replace it with the green lens provided.(Installation is the reverse of removal.).8 On the LED circuit board, locate the red/green jumper (SeeSchematic).The jumper should be in the red position perthe silk screen printing on the board. Pull gently upwardon the jumper, then shift it one pin over to activate thegreen LEDS.9 If the unit has remote capacity, LED remotes can beconnected using the violet (+) and yellow (-) wires. (SeeSchematic).10 Energize AC supply, LED display will come on.11 Replace the stencil cover assembly.12 Remove EZ Key to connect battery. Battery will not chargewith EZ key in place. Allow 24 hours for charging with 120or 277V input, 48 hours with 240V input.