Sounder Base ULCAS380, ULMAS850, ULFXN538LBS Effective April 2019Installation InstructionsModel No. BrandULCAS380 Eaton CooperULMAS850 Eaton MenvierULFXN538LBS Eaton JSBInstallation1. Fit the box in position using the mounting details below.2. Connect the unit according to the diagram below.3. Recommended Loop Cable Type: FIRETUF, FP2001. Mounting BaseI. Knock-out the required fixing holes.II. Fix to mounting surface using two suitable screwsIf the base deforms on an uneven surface. Loosen the screws ormove to a more flat position.When used with a detector, the installation and spacing shall bein accordance with the requirements for smoke detectors (NFPA72, Chapter 17).When installed with the blank cover,the installation and spacingshall be in accordance notification appliances(NFPA 72, Chapter 18.)2. Sounder AssemblyClip sounder onto base. If sounder needs to be removed use asmall screwdriver to unclip.3. Locking Tab (optional)Fit the locking tab into the squarehole on the shoulder.Finish assembly as stage 5.Remove by inserting a suitable tool(e.g. A thin screwdriver) into the holein the detector or cover, then rotatedetector or cover anti-clockwise.4. Fitting Detector or Cover5. Standard Connections (see diagram overleaf)Warning: Do NOT use high voltage tester if ANY equipment isconnected to the system.All connections are Power Limited.When the base is used with the blank cover: Multiple toneappliances which produce the three pulse temporal pattern forthe international evacuation signal [NFPA 72 (National Fire AlarmCode)], shall be used for evacuation use only. The base must notbe used for evacuation when used with a detector head.ote:N No addressing of the interface is required. See control paneloperation for details.50607080Locking tabrelease holein out4361-71102Sounder and Cover Sounder and Detectorø102øin outDo not use thisconnectionTerminate the screen as a floatingjoint to the rear of the base within thecable termination box50607080Locking tab50607080Locking tabrelease hole4361-71102Sounder and Cover Sounder and Detectorø102øTerminate the screen as a floating50607080S+S-F-ompatible AnalogueAddressable PanelLoop Startop Finish43102Sounder and Coverø50607080Locking tabrelease hole4361-71102Sounder and Cover Sounder and Detectorø102øTerminate the screen as a floatingjoint to the rear of the base within thecable termination box50607080Locking tabrelease hole4361-71102Sounder and Cover Sounder and Detectorø102øTerminate the screen as a floatingjoint to the rear of the base within the