Chengdu Ebyte Electronic Technology Co., Ltd. E22-400T30S User manualCopyright ©2012–2018,Chengdu Ebyte Electronic Technology Co.,Ltd. 19“Node 1” NETID is 08.“Node 2” NETID is 33.Primary repeater 1‘s ’ADDH\ADDL are 08,33.So the signal sent by node 1 (08) can be forwarded to node 2 (33)At the same time, node 1 and node 2 have the same address, so the data transmitted by node 1 can be received by node 2.② Secondary repeaterSecondary repeater’s ADDH\ADDL are 33,05.Therefore, Repeater 2 can forward the data of Repeater 1 to the network NETID: 05.Thus node 3 and node 4 can receive node 1 data. Node 4 outputs data normally, and node 3 has a different address thannode 1, so no data is output.③ Two-way repeaterAs shown in the figure: the data sent by node 1, the nodes 2, 4 can receive the data sent by node 2, 4, and node 1 can alsoreceive it.9 Configuration instructions on computer⚫ The following figure shows the E22-400T30S configuration host computer display interface, the user can switch to thecommand mode through M0M1, and quickly configure and read the parameters on computer.