Chengdu Ebyte Electronic Technology Co., Ltd. E34-2G4D20D User manualCopyright ©2012–2018, Chengdu Ebyte Electronic Technology Co.,Ltd. 97. Instruction formatIn setting mode(mode 3:M1=1, M0=1), it supports below instructions on list.( Only support 9600 and 8N1 format when setting)No. Instruction format Illustration1 C0 + working parameters C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and mustbe send in succession. ( Save the parameters when power-down )2 C1+C1+C1 Three C1 are sent in hexadecimal format. The module returns the saved parameters andmust be send in succession.3 C2 + working parameters C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and mustbe send in succession. ( Not save the parameters when power-down )4 C3+C3+C3 Three C3 are sent in hexadecimal format. The module returns the version information andmust be send in succession.5 C4+C4+C4 Three C4 are sent in hexadecimal format. The module will reset one time and they must besend in succession.7.1 Default parameterDefault parameter values:C0 00 00 18 00 40Model Frequency Address Channel Air data rate Baud rate Parity Transmitting powerE34-2G4D20D 2.4GHz 0x0000 0x00 - 9600 8N1 100mW7.2 Reading operating parametersInstruction format DescriptionC1+C1+C1In sleep mode(M0=1,M1=1),User gives the module instruction (HEX format): C1 C1 C1,Module returns the present configuration parameters.For example, C0 00 00 18 00 40.7.3 Reading version numberInstruction format DescriptionC3+C3+C3In setting mode(M0=1,M1=1),User gives the module instruction (HEX format): C3 C3 C3,Module returns its present version number, for example C3 39 xx yy.39 here means the module model (E39 series); xx is the version number and yy refers to the othermodule features.