12HRV installationLocationThe HRV must be located in a conditioned space where it will be possible to conveniently service the unit. Typicallythe HRV would be located in the mechanical room or an area close to the outside wall where the weatherhoods willbe mounted. If a basement area is not convenient or does not exist, a utility room may be used.Attic installations are not normally recommended due to:• The complexity of the installation• Freezing conditions in the attic• Difficulty of access for service and cleaning• No drain accessConnecting appliances to the HRV is not recommended. These include:• Clothes dryer• Range top• Stovetop fan• Central vacuum system• Bathroom exhaust fans unless they are specifically designed for this purposeThese appliances may cause lint, dust or grease to collect in the HRV, damaging the unit.Mounting – Wall Mount1. Attach bracket to wall2. Lift unit & slide nuts into slots on bracket3. Tighten screws to secure unit to bracket4. Ensert the safety screws & place wall bumpers to level off the unit.* Optional chain hanging kit available.• Install the unit close to theoutside wall on which thesupply and exhaust hoodswill be mounted.• Have a nearby power supply120 Volts, 60Hz. (powercord is 3 feet long)• Mount the unit as level aspossible in order to allowproper condensate drainage.• Have access to a waterdrain for the condensate ofthe unit during defrost.• Have a certain amountof heat around the unit(attic installation is notrecommended).• Installations close to theliving space, such as closets,should be design and tominimize noise or vibrationtransfers.• • Have access for futuremaintenance. (10” isrecommended for removalof core)Connecting any ofthese types ofappliances to theHRV will void yourwarranty. Safety screws (included)Place bumpers on backof unit (included)16” (406mm)