Troubleshooting SK550 1.1 V. 2.0215 Troubleshooting5.1 General troubleshooting procedure1. Try to solve the problem with the information in this manual.See § 5.3.2. If it is not possible to solve the problem with the information inthis manual, contact service. See § 5.2.5.2 Contact service1. Find the type plate on the rear of the machine. See § 3.1.4.2. Take a note of the model number and the serial number of themachine.3. Contact your supplier or manufacturer.See www.fast-fluid.com.5.3 Error messages and other faultsNoteSee the column Possible solution to solve theproblem. When the problem persists, contactservice. See § 5.2.Problem Possible cause Possible solutionThe display shows ‘E01’ The door is open. Close the door. See § 3.2.4.The display shows ‘E08’ Emergency stop switch is pressedduring running state.Release the emergency stop switch.See § 3.2.9.The display shows ‘E11’ The can is missing. Place the can. See § 3.2.4.The display shows ‘E50’ to‘E99’ Inverter is in error mode. Reset the machine. See § 3.2.10.The display shows user IDcode ‘0000’, but you havechosen another user IDcodeThe wrong user ID code is chosen. Contact service. See § 5.2.