OBID i-scan® Installation ID ISC.ANT1700/740-A /-BFEIG ELECTRONIC GmbH Page 34 of 74 M91201-5e-ID-B.docThen set the operating power, Transponder Parameters and ISO Host Mode:Step Action Note1 Select “Configuration”2Air Interface:“RF-POWER” (here 8W)„Mulitplexer Enable“„1 Input (Single Mode)“„No of Output Channels „(e.g. 2)„Antenna Active Time“100 x 5ms3 Set by clicking on „Apply“.4Transponder:Configure the parameters asfollows: „Driver“ – here ISO 15693 „Anticollision“ – enable „No of Timeslots“ –1 timeslot „Data Coding“ – 1 of 4 „AFI“ – DisabledNote: National RF regulations may require differentsettings. 7 Configuring the Reader in accordance withnational RF regulations5 Set by clicking on „Apply“.6Operating Mode:For antenna tuning the readermust be set to „Host Mode“.7 Set by clicking on „Apply“.