Installation in Recess or ClosetThis dryer MUST be exhausted outdoors.No other fuel burning appliance shall beinstalled in the same closet as theGAS DRYER.Your dryer needs the space around it for properventilation.DO NOT INSTALL YOUR DRYER IN ACLOSET WITH A SOLID DOOR.A minimum of 120 square inches (774.2 squarecm) of opening, equally divided at the top andbottom of the door, is required. Air openingsare required to be unobstructed when a door isinstalled. A louvered door with equivalent airopenings for the full length of the door isacceptable.Allow the following clearances for ease of installation:FRONT SIDES REAR TOPAlcove 0 (0 cm) 0 (0 cm) 0 (0 cm) 15″ (38.1 cm)Closet 1″ (2.54 cm) 0 (0 cm) 0 (0 cm) 15″ (38.1 cm)Closet door ventilation required: 2 louveredopenings each 60 square inches (387.1 square cm)—3″ (7.6 cm) from bottom and top of door.432160 sq. in.(387.1 sq. cm)0" (0 cm) 1" (2.54 cm)15"(38.1 cm)60 sq. in.(387.1 sq. cm)Closet door11Location of Your DryerDo Not Install the Dryer:Do not install the dryer in an area exposed todripping water or outside weather conditions.Do not install the dryer in an area where it willcome in contact with curtains, drapes, oranything that will obstruct the flow ofcombustion and ventilation air.Do not install the dryer on carpet.FloorMUST be solid with a maximum slope of 1″(2.54 cm).3210" (0 cm)Customer ServiceCare and CleaningSafety InstructionsInstallation Instructions