GE 15087 User Manual
Also see for 15087: Quick start guideUser manual
APPLICATIONThe GE Time Switches (56922, 15087, 15207) are universal, electromechanicaltime switches which can be field configured for various power supplyvoltages. The voltage options include 120VAC, 208/240VAC and 277VAC – allwithin the same unit! Selection of the desired supply voltage is easily achievedby positioning dipswitches on the printed circuit board assembly (consultDipswitches Configuration on back). The mechanism is mounted in a NEMAindoor or outdoor enclosure and is intended for the control of lighting, heating,air conditioning, pumps, motors, or general electrical circuits in residential,commercial, industrial and agricultural facilities.SPECIFICATIONSInput Voltage: 120 VAC, 208/240 VAC, or 277 VAC in all units basedupon dipswitch configuration.15087 NEMA 3R Indoor & Outdoor BM-A301US5-O215207 NEMA 1 Indoor BM-A301US5-I256922 NEMA 1 Indoor BM-A301US5-I215132 NEMA 3R Indoor & Outdoor EM-A301US9-O2Switch Rating: DPDT ModelsNormally Open Contacts40A Resistive, 120-277Vac.30A General Purpose, 120-277Vac.20A Resistive, 30Vdc1 HP, 120Vac ; 2HP, 240Vac ;20A Ballast, 120-277Vac.15A Tungsten, 120Vac5.4A Tungsten, 208-277Vac.800VA, Pilot Duty, 120Vac.720VA, Pilot Duty, 240-277Vac.TV-5, 120VacNormally Closed Contacts30A Resistive, 120-277Vac15A General Purpose, 120-277Vac15A Resistive, 30Vdc20A Ballast, 120-277Vac1/4HP, 120Vac; 1/2HP, 208-240Vac.290VA, Pilot, 120Vac.360VA, Pilot, 208-240Vac.NOTE: If loads are connected to both NC and NO contacts, both contacts aredecorated to 67% of the above values.ENVIRONMENTAL RATINGSAmbient Temperature: –40F to 130FHumidity: 0-95% RH, Non-condensingWIRING CONNECTIONSScrew clamp terminals for up to 2 AWG #8 wires per position. For supplyconnections, use 8AWG or larger wires suitable for at least 105° C. Use copperconductors only.LightsPower LED (Orange) – Light illuminates when power is applied tothe timerStatus LED (Green) – Light illuminates when power is applied to load.Included HardwareINSTALLATIONCAUTION: Before wiring or servicing, power to this time switch and theequipment it controls must be turned off. Turning off the time switch onlywill not prevent a shock hazard. Replace cover plate within housing beforesupplying power to time switch. If you are not comfortable installing thisdevice please contact a licensed electrician. Before installing this product readall instructions carefully.Removing Knockout1. Select knockouts to be used. Remove the inner 1/2” knockout by insertinga flathead screwdriver on the inner most ring and carefully punching theknockout loose. Remove slug. If the 3/4” knockout is required, remove theouter ring with pliers after removing the 1/2” knockout. Smooth edges witha knife if necessary.Please refer to Quick Start Guide for Examples and More Details.Mounting of the Time Switch BoxNOTE - Before mounting be sure to remove knockouts for the wires, (see QuickStart Guide)1. In order to mount the box you will need the 3 supplied anchors and 3supplied screws from the hardware list above. (Anchors included aredesigned for mounting on sheetrock.)2. Using the box as a template, mark with a pencil where the three pilot holeswill be drilled.Time SwitchWARNINGRisk of electric shock• Shut off power at fuse box or circuitbreaker box before installationRisk of fire• Do not use to control receptacleoutlets• Do not exceed electrical ratings• Use copper wire only with this deviceQTY Hardware3 M4 Anchors 1” Long3 M4 Screws 1” Long2 8 AWG Jumpers for 240V AC2 10 AWG Jumpers for 120V AC1 Wire Nut (For Ground Wires) |
Related manuals for GE 15087
manualsdatabase
Your AI-powered manual search engine