6 ATS2000/3000/4000/4500 Quick Programming Guide2. PROGRAMMING MAP1. Zone Database 1. Zone numberZone Type1. Zone name2. Zone type3. Reporting of zone6. Report alarm to CS 34. Report alarm to CS 15. Report alarm to CS 27. Report alarm to CS 48. Enable ALI for this zone9. Enable engineer reset for alarms10. Enable engineer reset for tampers13. Area / alarm group assignment11. Disable inhibit of the zone12. Enable Soak Test14. Test option15. Zone event flag16. Internal Siren Event flag17. External Siren Event flag20. Trigger event flag 2, armed alarm18. Keypad Buzzer19. Make all events 24 hour21. Trigger event flag 3, armed alarm22. Trigger event flag 4, armed alarm23. Trigger event flag 5, armed alarm24. Trigger event flag 6, armed alarm27. Trigger event flag 9, 24hr alarm25. Trigger event flag 7, disarmed alarm26. Trigger event flag 8, disarmed alarm28. Trigger event flag 10, armed alarm31. Trigger camera event in area DB29. Trigger event flag 11, armed alarm30. Trigger zone event flag when active32. Print zone when activeSimple/Advanced Menu*-AdvancedSimple menusAdvanced menusLegend27. Technical with Report28. Armed Alarm with reset29. 24 Hour Alarm with reset30. Fire door with reset31. Latching keyswitch32. Armed zone to event flag33. 24 hr Alarm and Inhibit34. Area Dis/Almgrp restr. Arm35. Area Almgrp restr. Arm Only36. Camera 5 count37. Camera 6 count38. Camera 7 count39. Camera 8 count40. Dis. Susp.Delay /Arm Alm41. Entry/Exit Fire door42. Entry/Exit Fire Door w. code43. Disarm zone to Event Flag44. Fire door with almgrp restr.45. (Event flag/Arm.Alm) Almgrp.restr.46. Disarm Alm/Arm Gen. Alm.47. Dis. Alm Susp./Arm Gen. Alm48. Camera 1 film out49. Camera 2 film out50. Camera 3 film out51. Camera 4 film out52. Camera 5 film out53. Camera 6 film out54. Camera 7 film out55. Camera 8 film out56. Fire door if No TZ4157. Technical Report And Screen58. Technical Screen59. 24 hr Alarm If No Tz 4160. Exit Terminator61. Entry/Exit hold off reporting62. Access hold off reporting63. Entry/Exit no arm check holdoffreporting64. Access no arm check holdoffreporting65. Engineering reset switch66. Final door set67. Latched detector68. Antimask detector69. Alarm (ACPO) zone70. KeyboxMenu 190. No type programmed.1. Disarmed alarm2. Armed alarm3. Entry/Exit alarm4. Access zone5. 24 hour alarm6. Pulsed keyswitch7. Camera suspicion zone8. Disarmed delay /Arm gen. alarm9. Reset delayed zones10. Do Not use!11. Disarmed delay alarm12. Restart exit timer13. Entry/Exit no arm check14. Access No arm check15. Fire door16. 24-hour local mains fail17. Do Not use!18. 24-hour local comms fail19. Comms fail led20. Zone to Event Flag 24-hr21. Firedoor with usercode22. Dis. Delay reset/Arm Alm23. Camera 1 count24. Camera 2 count25. Camera 3 count26. Camera 4 count33. Engineer walk testIntelligent Security & Fire Ltd