44Performance Data SheetModel: GE RPWFUse Replacement Cartridge RPWF.The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal tothe permissiblelimit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International againstNSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.The following pharmaceutical reduction claims have not been certified by NSF International. Claims tested and verifiedby independent laboratory:ContaminantReduction Average InfluentNSF specifiedChallenge ConcentrationAvg %ReductionAverage Product WaterConcentrationMax PermissibleProduct WaterConcentrationNSFTest ReportAtenolol 1088 ng/L N/A 99.5% 5.0 ng/L N/A J-00103221Fluoxetine 845 ng/l N/A 99.4% 5.0 ng/L N/A J-00103221Ibuprofen 898 ng/L N/A 98.8% 9.9 ng/L N/A J-00103726Progesterone 945 ng/L N/A 99.4% 5.5 ng/L N/A J-00103727Trimethoprim 403 ng/L N/A 99.5% 2.0 ng/L N/A J-0010322134-8708-7119-0EPA #070595-MEX-001© 2012 General Electric Company PC71879It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.See Installation Manual for Warranty information.Application Guidelines/Water Supply ParametersService Flow 0.5 gpm (1.89 lpm)Water Supply Potable WaterWater Pressure 25-120 psi (172– 827 kPa)Water Temperature 33º F - 100º F (0.6º C - 38º C)Note: While the testing was performed under standard laboratory conditions,actual performance may vary.Replacement Cartridge: RPWF. For estimated costs of replacement elementsplease call 1-800-626-2002 or visit our website at www.geapplianceparts.com.WARNINGTo reduce the risk associated with ingestion of contaminants:A ytilauqnwonknuforoefasnuyllacigoloiborcimsitahtretawhtiwesutonoDwithout adequate disinfection before and after the system. Systems certifiedfor cyst reduction may be used on disinfected water that may contain filterablecysts. EPA Establishment Number 070595-MEX-001.NOTICETo reduce the risk associated with property damage due to water leakage:DRead and follow use instructions before installation and use of this system.D5stallation and use MUST comply with all state and local plumbing codes.DDo not install if water pressure exceeds 120 psi (827 kPa). If your water pressureexceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbingprofessional if you are uncertain how to check your water pressure.KDo not install where water hammer conditions may occur. If water hammerconditions exist you must install a water hammer arrester. Contact a plumbingprofessional if you are uncertain how to check for this condition.KDo not install on hot water supply lines. The maximum operating watertemperature of this filter system is 100º F (38º C).KProtect filter from freezing. Drain filter when temperatures dropbelow 33ºF (0.6ºC).fielbasopsidehTK lter cartridge must be replaced every 6 months at therated capacity, or sooner if a noticeable reduction in flow rate occurs.For conditions of use, health claims certified by the California Department of PublicHealth, and replacements, see performance data sheet. California Departmentof Public Health Certification #11-2110. The contaminants or other substancesremoved or reduced by this water filter are not necessarily in all users’ water.Capacity 170 Gallons (643.5 Liters). Contaminant Reduction Determined by NSF testing.Substance Testedfor Reduction Average InfluentNSF specifiedChallenge ConcentrationAvg %ReductionAverage ProductWaterConcentrationMax PermissibleProduct WaterConcentrationNSF ReductionRequirementsNSFTest ReportChlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 97.4% 0.05 mg/L N/A ≥50% J-00102044Nominal ParticulateClass I, , ≥0.5 to < 1.0 μm 7,633,333 pts/mL At least 10,000 particles/mL 99.0% 71,850 pts/ml N/A ≥85% J-00106249Asbestos 109 MFL107 to 10 8 fibers/L; fibersgreater than 10μm in length 99.99% <1 MFL N/A ≥99% J-00102069Atrazine 0.009 mg/L 0.009 mg/L ± 10% 94.4% 0.0005 mg/L 0.003 mg/L N/A J-00102058Benzene 0.016 mg/L 0.015 mg/L ± 10% 96.4% 0.001 mg/L 0.005 mg/L N/A J-00102065Carbofuran 0.08 mg/L 0.08 mg/L ± 10% 98.8% 0.001 mg/L 0.04 mg/L N/A J-00102059Cyst* 104,750 cysts/L Minimum 50,000 cysts/L 99.99% 3 cyst/L N/A ≥99.95% J-00102057Lead pH @6.5 0.140 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00102052Lead pH @8.5 0.158 mg/L 0.15 mg/L ± 10% 98.3% 0.002 mg/L 0.010 mg/L N/A J-00102053Mercury @ pH 6.5 0.006 mg/L 0.006 mg/L ± 10% 91% 0.0003 mg/L 0.002 mg/L N/A J-00102054Mercury @ pH 8.5 0.006 mg/L 0.006 mg/L ± 10% 88.3%% 0.0007 mg/L 0.002 mg/L N/A J-00104087Lindane 0.002 mg/L 0.002 mg/L ± 10% 99% 0.00002 mg/L 0.0002 mg/L N/A J-00102063P-Dichlorobenzene 0.222 mg/L 0.225 mg/L ± 10% 99.8% 0.0005 mg/L 0.075 mg/L N/A J-00102067Toxaphene 0.015 mg/L 0.015 mg/L ± 10% 93.5% 0.001 mg/L 0.003 mg/L N/A J-001020612, 4-D Reduction 0.218 mg/L 0.210 mg/L±10% 99.9% 0.0001 mg/L 0.07 mg/L N/A J-0010206407020100-J%59≥A/NL/gm5100.0%7.79%01±L/gm003.0L/gm872.0COV*Based on the use of Cryptosporidium parvum oocysts.REPLACEMENTTNEMELESystem tested and certified by NSFInternational against NSF/ANSI Standard42 and Standard 53 in model GE RPWFfor the reduction of the claims specifiedon the performance data sheet.GEAppliancesAppliance ParkLouisville, KY 40225geapplianceparts.com