modifications reserved 10 User manual ML Series 350-1000 VA UPS 1.0 (GB)7 - SPECIFICATIONSML Series model : 350 500 700 1000RatingsVoltage Amperes (VA) / Watts (W) : 350 / 210 500 / 300 700 / 420 1000 / 600InputAC input voltage (Vac) : 220 - 240AC input voltage window (Vac) (mains) : 140 - 300V 140 - 300V 140 - 300V 160 - 265VMaximum AC input voltage (Vac) : 350Minimum start-up AC voltage (Vac) : 150 150 150 170Input frequency (Hz) : 50Input frequency range : nominal ± 10 %Typical no-load power consumption,normal operation (W) : 12 12 27 27AC input current (A) : 2.5 3.6 5 6.3AC input fuse (A) : 5 5 6.3 10OutputAC output voltage (Vac) : 230 (suitable for 220-240 Vac loads)AC output voltage tolerance : nominal ± 5% (before battery low)Output frequency (Hz) : 50Output frequency stability (Hz) : < ± 0.1 (battery operation)Output waveform : step sine wavePower factor : 0.6 (0.7 at 90% load)Transfer time (ms) : typically 4, max 10Buck/Boost voltage regulation : if the input voltage is within the input voltage window,the output voltage varies between 198-265VacBatteries (ratings given for 25ûC)Nominal voltage (Vdc) : 12 12 24 24Number x capacity (Ah) of batteries : 1x5 1x7 2x5 2x7Type : 12Vdc, sealed lead acid, maintenance freeService life : up to 6 years (depending on use)Recharge current (A) : 0.5 0.7 0.5 0.7Battery recharge time for 80%capacity (hours, approximation) : 3Runtime in minutesVA / Watts100/60 25 40 60 85350/210 3 8 14 24500/300 - 3 7 11700/420 - - 3 71000/600 - - - 3GeneralWeight (kg) : 6.5 7.5 11 13Dimensions (hxwxd, mm) : 150x110x300 150x110x420 150x110x450Enclosure / protection : steel-plastic / IP20Colour (operating panel / case) : RAL 9006 (aluminium) / RAL 7035 (light grey)EnvironmentSafety : EN 50091-1-1 (EN 60950)Electromagnetic compatibility : EN 50091-2Ambient temperature : -10 to +40ûC;Sound at 1 meter : < 35 dB(A)Maximum relative humidity : 95% (non-condensing)