13NOTE: The middle rail separating the twoopenings may need to be larger than the 3”(7.6 cm) minimum shown. Always refer to theindividual installation instructions packed witheach product for specific requirements.Combined Advantium and WallOven Installation:When installed in combination with asingle wall oven, use separate electricaljunction boxes.• Refer to the Advantium oven installationinstructions for electrical requirements ofthat product.• These connections must be madeby a qualified electrician. All electricalconnections must meet National ElectricalCode or prevailing local codes.NOTE: Additional clearances may berequired. Check to be sure the ovensupports above the Warming Drawerdo not obstruct the required interior depthand height. The middle rail separating theopenings may need to be larger than the2” (5.1 cm) minimum shown. Always refer tothe individual installation instructions packedwith each product for specific requirements.Warming DrawerCombined with Advantiumand Single Oven:Install a separate 120V, 60Hz, properlygrounded receptacle. See installationinstructions packed with each productfor specific requirements.Note: Install theoven only withspecific modelslisted on the labellocated on top ofthe oven.CabinetrySingle 30″ (76.2 cm)Oven Belowan AdvantiumSingle 30″ (76.2 cm) OvenBetween an Advantiumand a Warming DrawerCutout for 30″ (76.2 cm) Single Ovens only –Below an Advantium or Between anAdvantium and a Warming DrawerFor JTP30, JTP70, PT916, PT920, ZET938 models only.A3” (7.6 cm) Min.2” (5.1 cm) Min.Per AdvantiumRequirementPer WarmingDrawerRequirement3” (7.6 cm) Min.Per AdvantiumRequirement