MARK HOLESSelect the vent option that your installation willrequire and proceed to that section:Hood mounting screws (4)13 15⁄16″ (30″ hood)16 15⁄16″ (36″ hood) 1315⁄16″ (30″ hood)1615⁄16″ (36″ hood)Cabinet frontCenterlineElectrical access hole(in cabinet bottom)Wood shims (recessed-bottom cabinets only)Vertical ductaccess hole101⁄2″11⁄2″2″71⁄2″5″ 11⁄4″A. Outside top exhaust(Vertical duct—3 1⁄4″ x 10″ Rectangular)• Use the diagram or the hood as a template andmark the locations on the cabinet for ductwork,electrical wiring and keyhole screw slots.B. Outside top exhaust (Vertical duct—7″ Round)• Use the diagram or the hood as a template andmark the locations on the cabinet for ductwork,electrical wiring and keyhole screw slots.Hood mounting screws (4)1315⁄16″ (30″ hood)16 15⁄16″ (36″ hood)1315⁄16″ (30″ hood)1615⁄16″ (36″ hood)Cabinet frontCenterlineElectrical accesshole (in cabinet bottom)Wood shims (recessed-bottom cabinets only)Accesshole for 7″round duct101⁄2″11⁄2″2″71⁄2″5″Cabinetbottom 8″ DIA.HOLECUT HOLESCut holes at marked locations for duct and electricalwiring. For the vertical duct, cut out 3/4″ extratoward the front of the cabinet so you can move theduct freely when installing the hood. It may also easeinstallation by cutting the hole 10 1⁄2″ instead of 10″.FOR RECESSED-BOTTOMCABINETS ONLYRUN WIRESRun the electrical wires through the wall orcabinet according to National Electrical Codeand applicable local codes.NOTE: DO NOT turn the power on untilinstallation is complete.Cabinet Bottom12141315SCREW IN PARTWAYDrive a mounting screw (from the hardware packet)partway into each center of the narrow neck of thekeyhole slots marked on the cabinet bottom.FEED IN WIRESLift the hood into position and feed the housewiring through the wiring knockout.1617Wood shims (recessed-bottom cabinets only)Cabinet frontCenter line Electrical access hole(in wall)Hood mounting screws (4)Horizontal ductaccess holeCabinetbottom1315⁄16″ (30″ hood)16 15⁄16″ (36″ hood)3⁄4″1⁄8″33⁄4″51⁄4″ 51⁄4″71⁄2″1315⁄16″ (30″ hood)16 15⁄16″ (36″ hood)C. Outside rear exhaust(Horizontal duct—31⁄4″ x 10″ Rectangular)• Use the diagram or the hood as a template andmark the locations on the cabinet for ductwork,electrical wiring and keyhole screw slots.D. Recirculating (non-vented ductless—Available on JV5 Series models only)• Use the hood as a template and mark the locationson the cabinet for the electrical wiring and keyholescrew slots.• Since the hood is to be recirculated (not to be ventedoutside), do not cut out any vent openings in the wallor cabinet bottom.Wood shims• If the cabinets have front, side or back trim, make2 wood shims the width of the trim and attach themto the cabinet bottom recess on both sides. See Step12 for marking locations.51⁄4″51⁄4″Installation Instructions13