GE Multilin L90 Line Current Differential System B-67APPENDIX B B.4 MEMORY MAPPINGBD3D4 ...Repeated for Remote Device 22D3D8 ...Repeated for Remote Device 23D3DC ...Repeated for Remote Device 24D3E0 ...Repeated for Remote Device 25D3E4 ...Repeated for Remote Device 26D3E8 ...Repeated for Remote Device 27D3EC ...Repeated for Remote Device 28D3F0 ...Repeated for Remote Device 29D3F4 ...Repeated for Remote Device 30D3F8 ...Repeated for Remote Device 31D3FC ...Repeated for Remote Device 32Phasor Measurement Unit Communication (Read/Write Setting)D715 PMU 1 Port 2 D-CH-x Normal State (16 items) 0 to 1 --- 1 F108 0 (Off)D725 PMU 1 Port 3 D-CH-x Normal State (16 items) 0 to 1 --- 1 F108 0 (Off)Phasor Measurement Unit Recording Command (Read/Write Command)E4D4 PMU 1 Recording Clear Command 0 to 1 --- 1 F126 0 (No)E4D5 PMU 1 Recording Force Trigger 0 to 1 --- 1 F126 0 (No)Phasor Measurement Unit Recording (Read/Write Setting)E4DC PMU 1 Record Function 0 to 1 --- 1 F102 0 (Disabled)E4DD Reserved --- --- 1 F001 0E4DE PMU 1 No Of Timed Records 1 to 128 --- 1 F001 3E4DF PMU 1 Trigger Mode 0 to 1 --- 1 F542 0 (Auto Overwrite)E4E0 PMU 1 Timed Trigger Position 1 to 50 % 1 F001 10E4E1 Reserved --- --- 1 F001 0E4E2 PMU 1 Record PHS-1 (14 items) 0 to 14 --- 1 F543 1 (Va)E4F0 PMU 1 Record PHS-x Name (14 items) --- --- --- F203 GE-UR-PMU-PHS 1E560 PMU 1 Record A-CH-x (8 items) 0 to 65535 --- 1 F600 0E568 PMU 1 Record A-CH-x Name (8 items) --- --- --- F203 AnalogChannel 1E5A8 PMU 1 Record D-CH-x (16 items) 0 to 65535 --- 1 F300 0E5B8 PMU 1 Record D-CH-x Name (16 items) --- --- --- F203 Dig Channel 1Phasor Measurement Unit Frequency Trigger (Read/Write Setting)EB00 PMU 1 Frequency Trigger Function 0 to 1 --- 1 F102 0 (Disabled)EB01 PMU 1 Frequency Trigger Low Frequency 20 to 70 Hz 0.01 F001 4900EB02 PMU 1 Frequency Trigger High Frequency 20 to 70 Hz 0.01 F001 6100EB03 PMU 1 Frequency Trigger Pickup Time 0 to 600 s 0.01 F001 10EB04 PMU 1 Frequency Trigger Dropout Time 0 to 600 s 0.01 F001 100EB05 PMU 1 Frequency Trigger Block (3 items) 0 to 65535 --- 1 F300 0EB08 PMU 1 Frequency Trigger Target 0 to 2 --- 1 F109 0 (Self-reset)EB09 PMU 1 Frequency Trigger Events 0 to 1 --- 1 F102 0 (Disabled)Setting file template values (read only)ED00 FlexLogic™ displays active 0 to 1 --- 1 F102 1 (Enabled)ED01 Reserved (6 items) --- --- --- --- ---ED07 Last settings change date 0 to 4294967295 --- 1 F050 0ED09 Template bitmask (750 items) 0 to 65535 --- 1 F001 0Phasor Measurement Unit Records (Read Only)EFFF PMU Recording Number of Triggers 0 to 65535 samples 1 F001 0Table B–9: MODBUS MEMORY MAP (Sheet 59 of 59)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT