GE Lighting WIR-10-SR-C-D-W Installation Instructions Manual
• Read all instructions on both sides of thissheet first.• Plan all component locations carefully.• For use with 347 VAC only• Install in accordance with ALL local codes.• For indoor use only.General InformationTechnology: Passive Infrared (PIR)Electrical Ratings:347 VAC:• Incandescent/Tungsten – Max. load: 4.3 amps,1500W, 50/60 Hz• Fluorescent/Ballast – Max. load: 4.3 amps,1500W, 50/60 HzMotor Load: ¼ HP @ 125 VACTime Delays: Self-Adjusting, 15 seconds/test (10 minAuto), Selectable 5, 15, 30 minutesOperating Environment:• Temperature: 32° F – 104° F (0° C – 40° C)• Relative Humidity: 20% to 90% non-condensing• For indoor use onlyCoverage: Major Motion - 1000 sq. ft.Minor Motion - 300 sq. ft.Light Level Sensing: 0 to 200 foot-candlesHousing:• Durable, injection-molded housing. Polycarbon-ate resin complies with UL94V0.Size:• Mounting Plate Dimensions:4.195" H x 1.732" W (106.553 mm x 44 mm)• Product Housing Dimensions:2.618" H x 1.752" W x 1.9" D (66.5 mm x 44.5 mmx 48.26 mm)LED Indicators: Red indicates PIR detectionOperating Modes:• Automatic ON/Automatic OFF• Manual ON/Automatic OFFSpecificationsDescriptionThe WIR-10-SR-C-D Occupancy Sensing Wall Switch is a Passive Infrared (PIR) motion sensing light-ing control and conventional Wall Switch all-in-one, used for energy savings and convenience.PIR TechnologyThe sensor’s segmented lens divides the field of view into sensor zones, and detects the changes intemperature that are created when a person, or part of a person as small as a hand, passes into orout of a sensor zone.The WIR-10-SR-C-D allows the control of one load with one occupancy sensor switch.The sensor can be configured to enhance energy savings by setting the unit for manual ON opera-tion.In Automatic ON Mode, the lights turn ON automatically when a person enters the room. In ManualON Mode, the lights are turned ON by pressing the pushbutton. In either mode, the lights stay ON aslong as the sensor detects motion in the room. When the room is vacated, the lights turn OFF auto-matically after a preset Time Delay interval.The sensor includes self-adaptive technology that continually adjusts to conditions by adjusting sen-sitivity and Time Delay in Real-time. By adjusting sensitivity and Time Delay automatically, the sensoris maximizing the potential energy savings that are available in the particular application.The Daylighting feature prevents lights from turning ON, when the room is adequately illuminated bynatural light.Walk-Through feature maximizes energy savings by not leaving the lights ON after a momentary oc-cupancy. The sensor will switch the lights ON when it detects a person entering the area. If the sen-sor does not continue to detect motion 20 seconds following the initial activation, it willautomatically go to a shorter 2 minute Time Delay.CoverageLocationWhen installing the WIR-10-SR-C-D in a new junction box, choose the switch locationcarefully to provide optimum coverage of the occupied area. When replacing an exist-ing Wall Switch, bear in mind that there must be a clear Line-of-sight between the sen-sor and the area to be covered. Avoid pointing the WIR-10-SR-C-D directly into thehallway where it may detect passers-by.InstallationNOTE: Before you begin, read these instructions completely and carefully.WiringWIR-10-SR-C-D-WWIR-10-SR-C-D-VWIR-10-SR-C-D-AWIR-10-SR-C-D-GWIR-10-SR-C-D-BModel #The WIR-10-SR-C-D is designed for offices up to 300 square feet. Coverage testing has been per-formed according to the NEMA WD7 Guideline.The WIR-10-SR-C-D can be installed inany standard single gang box. It maybe installed in the same manner as anordinary Wall Switch.• Wire the WIR-10-SR-C-D as de-scribed in the wiring section.• Mount the WIR-10-SR-C-D in thejunction box.CAUTION: Before installing or performing any service on a GE system, the power MUST be turnedoff at the branch circuit breaker. According to NEC 240-83(d), if the branch circuit breaker isused as the main switch for a fluorescent lighting circuit, the circuit breaker should be marked“SWD.” All installations should be in compliance with the National Electric Code and all stateand local codes.NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescentlamps (CFLs) is shortened by frequent automatic or manual switching. Check with CFL and ballastmanufacturer to determine the effects of cycling.1. Make sure power is turned off at the branch circuit breaker.2. Wire units as shown in wiring diagrams per applicable voltage requirements.3. Mount unit to Wall Box.4. Turn power back ON at the branch circuit breaker and wait 2 minutes for the unit to stabilize.5. Make necessary adjustments. (See Checkout and Adjustments section)6. Install Wall Switch plate.,3620,Maximum coverage area mayvary somewhat according to roomshape and the presence of obstacles.8,Minor Motion, IRMajor Motion, IRLOAD347 VAC BLACK BLUENEUTRALGROUNDGREENWiring Diagram 1: 347 VAC single level single circuit wiring diagram347 VAC BLACK BLUENEUTRALGROUNDGREENLOAD 1 LOAD 2Wiring Diagram 2: 347 VAC single level switch dual level wiring using a toggle switch wiring dia-gramPassive Infrared Line Voltage Wallbox Occupancy Sensor (Ground Required)INSTALLATION INSTRUCTIONS |
Related manuals for GE Lighting WIR-10-SR-C-D-A
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine