POWER SUPPLY LOCATIONSGas Supply:• The pressure regulator must be connected in series with themanifold of the cooktop and must remain in series with thesupply line regardless of the type of gas being used.• The natural gas models are designed to operate at 5" watercolumn pressure. A regulator is required at the natural gassource to provide a maximum of 7" water pressure to thecooktop regulator.• The liquid propane models are designed to operate at 10"water column pressure. A regulator is required at the LPsource to provide a maximum of 14" water pressure to thecooktop regulator.• These gas cooktops are supplied with 1/2" NPT female gasconnection located at the left rear corner.• A minimum 5/8" dia. metal flexible line is required.– Use 5-foot long 5/8" flexible metal tubing. (Length mustcomply with local codes.)• For rigid connection, locate the pipe stub within area shown.• Install a manual shut-off valve in the gas line, in an easilyaccessible location.Electric Supply:These cooktops must be supplied with 120 volt, 60 Hz., andconnected to an individual, properly grounded branch circuitprotected by a 15 amp circuit breaker or time delay fuse.The power cord of this appliance is equipped with athree-prong (grounding) plug which mates with a standardthree-prong grounding wall receptacle to minimize thepossibility of shock hazard from this appliance.If the electrical service provided does not meet the abovespecifications, it is recommended that a licensed electricianinstall an approved outlet.DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVETHE THIRD (GROUND) PRONG FROM THE POWER CORD.DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.• Locate the electric supply within the area shown or withinreach of the cooktop’s six foot power cord.• To avoid tangling cord with items stored in the cabinet, locatethe receptacle on rear wall, inside the cabinet.Three Prong ReceptacleReceptacle Box Cover PlateThree Prong Plug6TOOLS REQUIRED• Saw• Measuring tape• Carpenter’s square• Large flat-blade screwdriver• Pipe wrenchGas Lineto CooktopLocate Gas Supply 2" MaximumProtrusion From Wall or on Floor 2" From Wall2"7" for 36" Models17" for 48" Models16"MATERIALS REQUIRED (not supplied)• Pipe and fittings as required• Manual gas line shut-off valve• Gas pressure regulator (supplied)• Gas-resistant pipe joint sealant• 5 foot, 5/8" AGA-certified flexible metal gas supply line(length must comply with local codes)– If required by local codes, use solid pipe fittings.NOTE: Purchase new flexible line. DO NOT USE OLD,PREVIOUSLY USED FLEXIBLE LINE.Installation Preparation