For answers to your Monogram,® GE Profile™ orGE® appliance questions, visit our website atge.com or call GE Answer Center ® service,800.626.2000.Listed byUnderwritersLaboratories220363KW Rating240V 3.4208V 2.6Breaker Size240V 20 Amps208V 20 AmpsNote: These ovens are not approved for stackable or side-by-side installations.Note: Cabinets installed adjacent to wall ovens must have anadhesion spec of at least a 194°F temperature rating. For 27”built-in single ovens, if marks, blemishes or the cutout openingis visible above the installed oven, it may be necessary to addwood shims under the runners and front trim until the marks oropenings are covered. Electric wall ovens are not approvedfor installation with a plug and receptacle. They must be hardwired in accordance with installation instructions.Note: Door handle protrudes 3" from door face. Cabinets anddrawers on adjacent 45° and 90° walls should be placed to avoidinterference with the handle.Installation Information: Before installing, consult installationinstructions packed with product for current dimensional data.AccessfromadjacentcabinetrequiredSuitablebracingto supportrunners2" x 4"or equiv.runnersB MIN.C MIN.Conduit 48-1/2" long32-1/2D10A Allow 3/4"for overlapover all edgesof cutoutLocatejunction boxeither 5" MIN.below cutoutfloor or 44"MIN. abovecutout floorMinimumcutout locationfrom floor(Minimum 15-5/8"from floor wheninstalled below built-inmicrowave oven)EGF20PK916SMGE Profile™ 27" Built-In Single Convection Wall OvenDimensions and Installation Information (in inches)Cabinet 27"A – Cabinet width required 27" min.B – Minimum cabinet depth 23-5/8"C – Opening width 25" min. - 25-1/4" maxD – Opening height 27-5/8" min. - 28-1/8" max.OvenE – Overall depth* 23-5/8"F – Overall height with trim 29-7/8" - 30-3/4"Overall height without trim 29"G – Overall width 26-5/8"*Depth including door handle is approximately 26-7/10" min. to26-8/10" max.AccessfromadjacentcabinetrequiredCLSuitablebracingto supportrunners 18"Over centerlineof cabinet(must support 275 lbs.)2" x 4" orequivalentrunners2" x 4"or equiv.runnersB MIN.C MIN.Conduit 48-1/2" long32-1/2D10A Allow 3/4"for overlapover all edgesof cutoutLocatejunction boxeither 5" MIN.below cutoutfloor or 44"MIN. abovecutout floorMinimumcutout locationfrom floor(Minimum 15-5/8"from floor wheninstalled below built-inmicrowave oven)EGF20Specification Revised 10/07