– 7 –Dimensions and ClearancesThe following MINIMUM clearance dimensions mustbe maintained.13″ MAX. Depth of uprotectedoverhead cabinets30″ MIN.Clearance fromcountertop tounprotectedoverheadsurface2″ MIN. Clearancefrom cutout toside wall on theleft of the unit15″ MIN. Heightfrom countertopto nearestcabinet on eitherside of unit2″ MIN.Clearance fromcutout to sidewall on the rightof the unitIf a 30-inch clearance between the cookingsurface and overhead combustible materials ormetal cabinets cannot be maintained, a minimumclearance of 24 inches is required and theunderside of the cabinets above the cooktop mustbe protected with not less than ¼-in. insulatingmillboard covered with sheet metal not less than0.0122 inches thick.20-7/8″ (21″ SS)Depth on Monogram ZEU36Kis 21-1/4″ @ center.33-3/4″Cooktop36″(36-1/8″ SS)18-7/8″3-1/4″ Front4-5/8″ Rearat the conduitlocation6-1/4″ Rearon Model PP975& PP980Overall Cooktop Dimensions - 30-in. Models33-3/4″Cooktop29-3/4″(29-7/8″ SS)18-7/8″3-1/4″ Front4-5/8″ Rearat the conduitlocation6-1/4″ Rearon Model PP945& PP95021-3/8″ (21-1/2″ SS)5″ Min.Vertical ClearanceThere must be 5 inches minimum vertical clearancebetween the cooktop bottom and any combustiblesurfaces.Make sure the wall coverings, countertop andcabinets around the cooktop can withstand heat upto 200°F (93°C) generated by the cooktop.Install junction box sothat it can be reachedthrough the front ofthe cabinet.16″Min.Note: The junction box must be located whereit will allow considerable slack in the conduit forserviceability.Overall Cooktop Dimensions - 36-in. ModelsW all covering,cabinets andcountertop mustwithstand heatup to 200°F ( 93° C ).