10OK>5 sec.1234567OK1234567OK1234567Menu 3: Configuration of CPLThis menu allows associating the unit to the remote CPL programmer connected to the samepower grid.In menu 3 press the “+”for 5 seconds. CPL message will start blinking.Switch the CPL programmer, remote control desk to the “association” mode (seecorresponding manual). Press shortly the “+”key. “EnrE” message displays on thescreen and then "CPL" message confirming the association.Press “OK” key to proceed with the following setting.Menu 4: Backlight time settingsAdjustable backlight is available from 0 to 225 seconds in 15 seconds steps (90 seconds bydefault).To modify press “+” or “–”, keys, then press the “OK” to store and proceed with thenext setting.Menu 5: Selection of temperature display in AUTO operation mode.1 = Permanent display of the premises temperature.0 = Permanent display of the set point temperature.To modify press “+” or “–”, keys, then press the “OK” to store and exit theconfiguration mode.4. - CLEANING AND MAINTENANCEThe radiators do not precise any special maintenance providing thermal comfort during large periods. Clean dust with a dry, soft cloth only whenthe unit is disconnected and cold.Do not use solvents or abrasive products for cleaning.After the heating season disconnect the radiator with the switch located on the back surface of the radiator.This thermal radiator has been manufactured under an assured quality system using environment friendly processes.Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way.5. - TROUBLESHOOTING- The thermal radiator does not heat. Check the heater or the air inlets are not covered.- The room does not reach therequired temperature.Check the selected temperature is in accordance with the desired temperature. Maybe the room needsmore heating power.- “-9.9ºC” ó “99.9ºC” message isdisplayedSensor wrong connection. Contact the after sale service.- “d2” or “d3” message is displayed Sensor wrong connection. Contact the after sale service .-“dEF” message is displayed CPL connection trouble. Contact the after sale service.- Time settings are lost There was electric supply shortage or the unit had been disconnected by the main switch- The keyboard does not respond If the bloc message is displayed, the thermal radiator keyboard is locked. Hold two central keysfor several seconds to unlock the keyboard.