Special mode: Additional electrical switching devices (e. g. remote controlsystems, pressure switches) can be used only in the special mode.Activating the special mode:1. When switching on, press the On/Off button ß8a for 8 seconds.During the first 5 seconds, the green LED is illuminated;then the LED blinks for 3 seconds.2. When the green LED illuminates again after 8 seconds,let go of the On/Off button ß8a .Deactivating the special mode:1. Plug the mains plug into an energised mains socket.The pump starts of its own accord.2. Press the On/Off button ß8a . The pump switches off.3. When switching on, keep the On/Off button ß8a depressed for8 seconds until the green LED no longer flashes.safe-pump-function: The safe-pump function uses the LED status display to alert theuser that there is no water flow. In addition, it acts as Dry-Run-ning Safety, guarding against pump damage if the delivery sideis closed too long (e.g. closed valves) or if the water supply fails(e. g. empty cistern).LED flashes green: Normal operationLED flashes orange: No water flow for at least 20 secondsLED shines red: No water flow for at least 5 minutes(pump has switched off automatically)LED flashes red: Alarm! Pump was started 3 times within20 min. without water flow. (Pump canno longer be started for 5 min. to allowcooling, after which the LED shines red)5. Putting into StorageOverwintering / Storage:9Before the start of the frost period the Garden Pump should bestored protected from frost.1. Open the water drain screw 9.The Garden Pump drains.2. Store your Garden Pump so that it is protected from frost.Disposal:(in accordance withRL2002/96/EC)The product must not be added to normal household waste.It must be disposed of in line with local environmental regulations.6. MaintenanceDANGER! Electric shock!Risk of injury due to electric shock.v Disconnect Garden Pump from the mains beforecarrying out maintenance.Cleaning the filter: If the filter is dirty it has to be cleaned.A6 1. Close all shut-off valves,if any, on the suction side.2. Unscrew and remove cover 6of the filter chamber.3. Draw out filter unit verticallyupwards.4. Hold beaker 0 firmly, turnfilter q anti-clockwise 1 anddraw out 2 (bayonet fitting).5. Clean beaker 0 underrunning water and clean thefilter q e. g. with a soft brush.6. Refit filter again in reverse order.12A0Flush through Garden Pump: The pump must be flushed through after discharging chlorinatedswimming pool water.1. Pump through lukewarm water (max. 35 °C), possibly addinga mild cleaning agent (e.g. detergent) until the pumped waterruns clear.2. Remove residuals according to the waste disposal lawsapplicable in your area.7. Trouble-ShootingDANGER! Electric shock!Risk of injury due to electric shock.v Disconnect Garden Pump from the mains beforetrouble-shooting.Free the impeller:"An impeller blocked by dirt can be freed again.v Turn the impeller bolt w using a screwdriver.This will free the blocked impeller.16GB17GB