8. Available accessoriesGARDENA Fitting For optimum utilisation of the pumpingcapacity of the pump.Art. 1723 / 1724GARDENAPump Connection SetIf the hose connection is to be detachedfrequently.Art. 1752For Art. 1489/1492 only:GARDENA Dry-RunningSafety *Deactivates the pump automatically ifthe pumped medium fails to flow.Art. 1741For Art. 1489/1492 only:GARDENA ElectronicManometric Switch *With Dry-Running Safety. Ideal for convertinga pump into a pressure tank unit.Art. 1739* GARDENA Dry Running Safety / Electronic Manometric Switch must not be installed directly on the pump,as they must not be submerged in the water.9. Technical DataArt. 14895500/5 inoxArt. 14926000/5 inoxArt. 14996000/5 inoxautomaticRated power 850 W 950 W 950 WMax. delivery capacity 5,500 l/h* 6,000 l/h* 6,000 l/h*Max. pressure /Max. delivery height 4.5 bar / 45m 5.0 bar / 50m 5.0 bar / 50 mMax. submersion depth 19m 19m 19mPower cable 22m H07 RNF 22m H07 RNF 22m H07 RNFPump connection 40mm (1 1/4")female thread40mm (1 1/4")female thread33mm (1")female threadMin. water level for operation(from the top edge of the filter) > 15cm > 15cm > 15cmWeight (without cable) approx. 7.5 kg 8.25 kg 9 kgFastening rope 22m 22m 22mCasing diameter < 98mm (max.) < 98mm (max.) < 98 mm (max.)Max. media temperature 35 °C 35 °C 35 °CMains voltage / mains frequency 220 – 240 V / 50 Hz 220 – 240 V / 50 Hz 220 – 240 V / 50 Hz* If used in a well pipe of 10 cm diameter, the max. delivery capacity is not reached.10. Service / WarrantyWarranty: GARDENA guarantees this product for 2 years (from date ofpurchase). This guarantee covers all serious defects of the unitthat can be proved to be material or manufacturing faults.Under warranty we will either replace the unit or repair it freeof charge if the following conditions apply:• The unit must have been handled properly and in keeping withthe requirements of the operating instructions.• Neither the purchaser or a non-authorised third party haveattempted to repair the unit.The wear part turbine is excluded from the warranty.Pumps damaged by frost are excluded from the warranty.This manufacturer’s guarantee does not affect the user’s existingwarranty claims against the dealer / seller.If you have any problems with your pump, please contactour Service or return the defective unit together with a shortdescription of the problem – in case of guarantee, witha copy of the receipt – postage paid to one of the GARDENAService Centres listed on the back of this leaflet.14GB15GB