Problem Possible Cause RemedyBattery shear does not start.(L1) flashes green [ Fig. O2 ]Battery is empty. v Charge the battery.Battery shear does not start.Error-LED ¥ flashes red [ Fig. O2 ]Blade is blocked (overcurrent). v Remove the obstacle.Battery shear can no longer be stopped Start lever is stuck. v See 1. SAFETY.Error-LED ¥ illuminates Battery error / battery defective. v Contact the GARDENA Service.NOTE: For any other malfunctions please contact the GARDENA service department.Repairs must only be done by GARDENA service departments or specialist dealers approvedby GARDENA.6. TECHNICAL DATABattery Shear Unit Value(Art. 9853)with grassbladeValue(Art. 9854)with shrubbladeValue(Art. 9856)with grassbladeValue(Art. 9857)with shrubbladeStrokes 1/min 1000 1000 1000 1000Width of grass blade mm 80 – 80 –Length of shrub blade cm – 12.5 – 12.5Weight g 575 640 635 700Sound pressure level LPA 1)Uncertainty kPAdB (A) < 703< 703< 703< 703Battery Shear Unit Value(Art. 9853)Value(Art. 9854)with shrubbladeValue(Art. 9856)Value(Art. 9857)with shrubbladeSound power level LWA 2)measured / guaranteedUncertainty kWAdB (A) 79 / 800.3579 / 800.4Hand/arm vibration avhw 1)Uncertainty kam/s2 < 2.51.5< 2.51.5< 2.51.5< 2.51.5Measuring process complying with: 1) EN 60745-2-15; 2) RL 2000/14/EC31EN9853-20.960.01 A6 Short.indb 31 06.08.18 13:37