5112.3. Factory ResetThe Control Panel can clear all programmed parameters and reset IP defaults back to FactoryDefault when either Local Reset or Remote Reset is applied.Once the System Reset is executed, all the programmed data & IP values will returned to itsdefault value, and all the learnt-in devices will be removed. You have to reprogram and learn inthe device one by one again.z LOCAL RESETStep 1. Power down Control Panel and remove the batteryStep 2. Apply power while holding down the S key.Step 3. Release the S key when a tone is heard, Test Mode will be displayed.Step 4. Enter the following keys sequence: STSTSTST, OKStep 5. Press the keyStep 6. All programmed parameters are reset to factory default setting.Step 7. If more than 17 incorrect keys entered, the unit will revert to normal Alarm On mode.z REMOTE RESETStep 1. Tick the Kept current network setting box to keep the current Network settings.Otherwise, the system will reset its value back to factory default.Step 2. Press Yes to continue the Reset procedure.Step 3. Wait for 1 min and do NOT power off during this time.Step 4. Once reset is complete, it will automatically reboot the CTC-1745 IP Panel..