GARLAND HALF SIZE ELECTRIC CONVECTION OVEN MODEL:MCOE5L INSTALLATION/OPERATION MANUALPage 6 Part Number: 4516833 rev E 5/16INSTALLATIONKNOCKOUTPLATETERMINALBLOCKBODY SIDECONTROL PANELASSEMBLYProper placement of the oven will ensure operatorconvenience and satisfactory performance.Adequate clearance must be provided for cleaning,servicing, and proper operation. (Refer to chart on page 4for minimum clearances.)Electrical ConnectionBefore attempting the electrical connection, the ratingplate should be checked to confirm that the oven’selectrical characteristics and the electrical supply arecompatible. The plate is located on the inside surface ofthe control panel/body side.1. Open the oven door to reveal the control panelmounting screws.2. Remove all screws attaching the control panelassembly to the oven.3. Next remove the screws mounting the body side to theoven in the front and back.4. Remove the knockout plate at the rear of the oven andmount the appropriate Size BX connector to fasten thecord. Re-attach the knockout to the oven.5. Pass the cord through the bx connector leavingenough length to reach the terminal block.6. Strip just enough wire to insert into the terminal block.7. Tighten terminal block screws and the screws in the BXto clamp the cord.8. Verify all electrical connections are correct. Re-attachthe body side and control panel assembly.Visually inspect all electrical connections. A wiring diagramis affixed to the inside surface of the control panel/bodyside section.Installation of the wiring must be made in accordance withUL 197, Commercial Electric Cooking Appliance Standards,local codes, and the National Electrical Code, ASNI/NFPA 70-1990, in regard to:a. Switch panel sizeb. Overload protectionc. Wire typed. Wire sizee. Temperature limitations of wiresf. Method of connection, (conduit, cable, etc.)