PART #4526396 (03/30/10)GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION SERVICE MANUALPage 39PROBE CALIBRATIONMonthly�Calibration�of�Grill�Temperature�ZonesTools: Digital Pyrometer with Surface ProbeWarning: PERSONAL INJURY FROM BURNS MAY RESULTWHEN COMING IN CONTACT WITH HOT COOKINGSURFACES.NOTE: Probe Calibration of grills is done with releasematerial sheets “OFF”.PLEASE�FOLLOW�THESE�INSTRUCTIONS�EXACTLY��AS�THEY�APPEAR�BELOW:1. The upper platens and lower grill plate should be atoperating temperatures to perform this calibrationprocedure. Press the or button to select a“CLAM” operation and allow the grill to reach the settemperature and stabilize, (approximately 30 minutes).2. PRESS and HOLD the button for approximately3 seconds, or until the controller will display:“PROBE CAL”.3. PRESS the button to display the first temperaturezone to be calibrated. The first zone to be calibrated is“FRONT TEMP CAL”. The zones are displayed in order ofFRONT TEMP CAL, MIDDLE TEMP CAL, BACK TEMP CAL,TOP TEMP CAL.MWE3W: The electric grill’s thermocouple probes arelocated front to rear, as shown in the diagram to theright. Each upper platen has one thermocouple in thecenter.MWG3W: The gas grill’s thermocouple probes arelocated in the center of each lane, as shown in thediagram to the right. Each upper platen has onethermocouple in the center.4. Select a heat zone display using the or buttons.5. Allow at least 5 seconds for the pyrometer to respondand stabilize. Note the temperature on the pyrometer.6. If the temperature on the grill control display does notmatch the temperature on the pyrometer, adjust thetemperature on the grill control accordingly. Thebutton will increase the displayed temperature in one,(1) degree increments. The button will decrease thedisplayed temperature in one, (1), degree Increments.NOTE:�During step 6, the control should be soundinga high-pitched tone. The temperature can only beadjusted if this tone is sounding. If the control is silent,the temperature will not change.7. PRESS the button to lock the calibrated temperatureinto the controller.8. Press the or button to select the next heat zone.9. Move the pyrometer’s surface probe to the newlyselected heat zone and repeat steps 5, 6, and 7.10. Repeat the procedure for each of the heat zones.11. Continue to cycle through each heat zone repeatingthe sequence until all temperatures are within 1°.12. Exit the program mode by pressing the button 2x.The controller will return to its previous state in theNormal Operating Mode.THERMOCOUPLE�LOCATIONSFRONTOF GRILL6.110[155mm]5.896[150mm]18.000[457mm]6.110[155mm]24.000[610mm]PLATEN THERMOCOUPLELOCATIONS (VIEW FROM BOTTOM)9.360[238mm](FROM FRONTOF PLATEN)5.750[146mm]36.000[914mm]12.814[325mm]19.732[501mm]11.500[292mm]FRONT & REAR PROBE POSITIONS AREAPPLICABLE TO ELECTRIC GRILLS ONLY