400W Series Installation Manual Page 5-5190-00356-02 Rev. E5.3.2 MAIN RS-232 CONFIG PageSelect the MAIN RS-232 CONFIG Page (see Figure 5-2).Change the selectable RS-232 inputs and/or outputs tomatch that of the equipment installed in the aircraft.NOTEInterfacing systems listed in the following tables are provided for reference only. Referto Appendix G to determine if the interface to a particular system is approved under the400W/500W Series AML STC.CHANNEL INPUTSSelection DescriptionOff No unit(s) connected to input of this channel.Arnav/ei-fuel Serial fuel flow information from the following units:ARNAV FC-10, FT-10Electronics International FP-5LCrossfill Serial transfer of flight plans and user waypoints between two 400W/500WSeries unitsGDL 69 Serial data input for in-flight access to weather and messaging from thefollowing units:Garmin GDL 69/69AIcarus-alt Serial altitude data from the following units:Icarus Instruments 3000Sandia SAE5-35Garmin GTX 327 TransponderTrans-Cal Industries IA-RS232-X, SSD120ACK Technologies A-30 (Mod 8 and above)Ryan TCAD Traffic information from a Ryan TCAD 9900B or 9900BX Series system.Shadin-adc Serial air data information from the following units:Shadin ADC 200, 200+, 2000Shadin-alt Serial altitude data from the following units:Shadin 8800T, 9000T, 9200TShadin-fadc Serial air data and fuel flow information from the following units:Shadin 9628XX-X Fuel/Air Data ComputerINSIGHT TAS 1000 Air Data ComputerShadin-fuel Serial fuel flow information from the following units:Shadin 91053XM Digital Fuel Management SystemShadin 91204XM Digital Fuel Management SystemJP Instruments EDM-700 or EDM-760 Engine MonitorWX-500 Lightning strike information from an L3 Communications WX-500Stormscope.Figure 5-2. MAIN RS-232 CONFIG Page