1- Connect all outputs & keypadsQuick Start Cardin.yt-7-ce™ European version3- Select spa configuration (if prompt on startup)3At first startup the keypad displaywill show Lx or LLx, where « x »representing the config. number. Somespa packs come with a pre-selectedconfig. and you may skip this step ifyour system automatically starts up1.Use the Up/Down key to choose thenew low level configuration number.Press the Program2 key to confirm theselection.211 phase connectionPhase jumpers PositionPJ1 P7-P13PJ2 P10-P742 phase connectionPhase jumpers PositionPJ1 P7-P10PJ2 P13-P743 phase connection (default)Phase jumpers PositionPJ1 P7-P10PJ2 P11-P133 phase Delta connectionPhase jumpers PositionPJ1 P7-P10PJ2 P13-P742- Connect the main powerCorrect wiring of the electrical servicebox, RCD, and pack terminal block isessential. Power must be off duringthis step.input voltage: 230 V, 50 Hz (line-to-Neutral) input voltage: 230 V, 50 Hz(line-to-line)WARNING! All connections must be made by a qualified electrician in accordance with the national electrical code and anystate, provincial or local electrical code in effect at the time of the installation. This product must always be connected to circuitprotected by a residual-current device (RCD).Determine jumper positions for number of phases4- Select breaker current98Specify the current rating and the number of phases of the RCD used to ensure safe and efficient current mangement (and no RCD trippings).2 3 341Light outputs(P34 always on, P35 relay controlled)Main powerentry connectionHeaterconnectionsHeaterBonding lugsA1A2A3A4C3C2C1G C HLC1C2C3H L GCA4A0A3A2A1H L GC Optionalfloating connector(Part #9920-401346)C1 - Main keypad connectorCO - Communication links (2 ports)in.touch, in.stik, Aux keypad in.k112,Swim Spa com. cable, etc.PJ2PJ2PJ1N N L3NL1PJ2 PJ2PJ2PJ1 PJ1PJ1L1 L1L1L2 L2L2L3G G GGAMP ports (A0 to A4,and C1 to C3) for pumps& accessories. Functionvaries per configuration(see next page).1 Note: To re-enter the low levelselection menu, hold the Pump 1key for 30 seconds.Note: For the Color keypad series,select Settings menu, go intoElectrical config and choose theappropriate Low level.2 Note: If the keypad does not have aProgram or Filter key, use the Lightkey instead.For more information, see ourwebsite: www.geckoalliance.comPress and hold the Program key for20 seconds until you access thebreaker setting menu.Note: For the Color keypad series,select Settings menu, go into Electri-cal config and choose Input current.The values displayed by the systemcorrespond to the maximumamperage capacity of the RCD.Use the Up/Down key to select thedesired value. Then press the Programkey to confirm the selection.Note: If the keypad does not have theProgram or Filter key, use the Lightkey instead.Current setting for each phase setting# of phases Current setting range1 10 to 48 A2 10 to 20 A3 10 to 16 AChoose the number of phasessupplying your spa (1-3). Use theUp/Down key to select the desiredvalue. Then press the Program key toconfirm the selection.For more information, see ourwebsite: www.geckoalliance.com