6.6www.geniecompany.com 03-12OPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEARSetting Open and Close Modes (Constant vs Momentary Contact)OPEN MODE MOMFigure 10NOTE: Momentary contact (MOM) or Constant Reverse (C-REV) may not be usedunless both the OPEN and CLOSE Limits have been set.In situations where an external reversing device is either not installed or notoperating properly, Constant Contact (C-STP) MUST BE USED.NOTE: During adjustment of a Travel Limit, the Open and Close Modes willautomatically fail-safe to Constant Contact until the Limit has been set or reset. Atthat time the Open and Close Modes will revert to their previous setting.CALRUNSCROLLOPEN CLOSERUSETCLEARSCROLLCALRUNCALRUNSCROLLOPEN CLOSERUSETCLEARCALRUNSCROLLWARNING: Before momentary contactcontrol can be used, an external reversing device such asa photocell system or sensing edge switch must be used.See pages 5.6-5.7 for installation of entrapmentprotection devices.OPEN1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.2) Press SCROLL until display reads “OPEN MODE>MOM” or“OPEN MODE>C-STP.”Figure 10.• MOM=momentary contact, meaning you press and release theOPEN or CLOSE key and the door will continue to moveuntil it reaches its travel limit. (See NOTE)• C-STP=constant contact-stop, meaning if you release the key priorto the door reaching its travel limit, the door will stop.3) Press SET/CLEAR key to toggle between “OPEN MODE>C-STP” or“OPEN MODE>MOM” on the display.4) Press a SCROLL key to shift to a new function and lock in the setting.5) Press CAL/RUN to return to run mode.CLOSE1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.2) Press SCROLL until display reads “CLOSE MODE>MOM,”“CLOSE MODE>C-STP” or “CLOSE MODE>C-REV.” Figure 10.• MOM=momentary contact, meaning you press and release theOPEN or CLOSE key and the door will continue to moveuntil it reaches its travel limit. (See NOTE)• C-STP=constant contact-stop, meaning if you release the key priorto the door reaching its travel limit, the door will stop.• C-REV=constant contact-reverse, meaning if you release the keyprior to the door reaching its travel limit, the door willreverse direction. (See NOTE)3) Press SET/CLEAR key to toggle between “CLOSE MODE>C-STP” or“CLOSE MODE>C-REV” or ”CLOSE MODE>MOM” on the display.4) Press a SCROLL key to shift to a new function and lock in the setting.5) Press CAL/RUN to return to run mode.Heavy Duty OperatorGCL-GT