Operator's Manual Fifth Edition · Second Printing8 GS-2668 RT • GS-3268 RT Part No. 133534Electrocution HazardsThis machine is not electrically insulated and willnot provide protection from contact with orproximity to electrical current.Maintain safe distances from electrical power linesand apparatus in accordance with applicablegovernmental regulations and the following chart.Line Voltage Required Clearance0 to 50KV 3.05 m50KV to 200KV 4.60 m200KV to 350KV 6.10 m350KV to 500KV 7.62 m500KV to 750KV 10.67 m750KV to 1000KV 13.72 mAllow for platform movement, electrical line sway orsag and beware of strong or gusty winds.Keep away from the machine if it contactsenergized power lines. Personnel on the ground orin the platform must not touch or operate themachine until energized power lines are shut off.Do not operate the machine during lightning orstorms.Do not use the machine as a ground for welding.Tip-over HazardsOccupants, equipment and materials shall notexceed the maximum platform capacity.Machine without capacity indicator:Maximum capacityGS-2668 RT 567 kgGS-3268 RT 454 kgMachine with capacity indicator:The maximum capacity varies with the height of theplatform.Maximum capacity - GS-2668 RTMaximum occupants 4Height of Platform Maximum Capacity7.9 m 567 kg6.8 m 835 kg4.8 m 975 kg2.7 m 835 kg1.7 m 567 kgMaximum capacity - GS-3268 RTMaximum occupantsIndoor use 4Outdoor use 2Height of Platform Maximum Capacity9.8 m 454 kg7.6 m 850 kg5.8 m 919 kg2.7 m 690 kg1.8 m 454 kgWork Area Safety