©2011 The Genie Company 9/20115WARNINGs Make sure doorway is in view and clear of obstacles andpeople to avoid injury or damage to property.s DO NOT operate this unit from wall console before LIMITSand FORCE are set. Severe damage to the opener can occur.s The bullet MUST be engaged to carriage BEFORE settinglimits. See Installation Poster (if provided) or callCustomer Service at 800-35-GENIE or visitwww.geniecompany.com.NOTE: If bullet has NOT been engaged tothe carriage, do so no .PROGR2Please note that there is a 30 second timeout betweeneach programming step.If you see two flashing RED LEDs, you have initiateda timeout.In the evw See page 9.CONTACT REVERSE TESTThe Force and Limit settings MUST be COMPLETEDbefore performing Contact Reverse Test.1. Test.Place a 2" x 4"board (laid flat)under center ofdoor opening.2. Adjustment, if needed.s If the door stops before it contacts the boardWARNINGA moving door can cause serious injury or death.1. Keep people clear of opening while door is moving.2. Do NOT allow children to play with opener, includingwall console, remote, or wireless keypad.3. During programming, door opener could begin to run,so stay away from moving door and its parts.Once the Contact Revese Test is complete,continue with programming Remotes.or it does not reverse, it may be due to an improperly setdown limit. Repeat TRAVEL LIMITS program and Test again.Repeat as needed until door passes test. For further helprefer to Maintenance &Troubleshooting, page 13.ent of a timeout you must restart at beginning.Press & hold2 seconds or untilLEDs react. Release.Press & hold2 seconds or untilLEDs react. Release.Long LED turns Blue,Round LED OFF. Then Long LED OFFRound LED Flashing.Long LED turns Blue, then flashes.Press & holduntil door is fullyopen. Then release.Press &Release.DOOR LIMITS ARE SETSET FORCE NEXTPROGRAMSETFLASHINGDOOR FULLY OPENDOOR FULLY CLOSEDOFF ORED REDFFPress &Release.PROGRAMSETPress &Release theOpen/Closebutton.DOOR CLOSES.s When door contacts board,it must stop and reverse direction(within 2 seconds) to the fullyopen position.OFF OFFAMMING LIMITSTRAVEL LIMITSUP LIMITDOWN LIMITDoor fully closes.Door fully opens.FORCE CONTROLPress &ReleaseOpen/Closebutton.ACTION INDICATION/RESULTACTION INDICATION/RESULTPress &ReleaseOpen/Closebutton.ON WALL CONSOLEPress &Release theOpen/Closebutton.FORCE CONTROL IS SET12121345623DOOR OPENS.ACTION LED INDICATION/RESULTOFFOFFONBLUEBOTH FLASH BLUEFLASHINGPress & holduntil door is fullyclosed. Then release.BDuring the initial settingof the limits- the LEDs willturn to RED—NOT OFFoth BLUE then LEDs Off confirms limit set.OFF OFFBOTH FLASH BLUEBoth BLUE then LEDs Off confirms limit set.