First Edition • Second Printing Operator's ManualOperating InstructionsPart No. 1286582GT S®-60 XC™ • S®-65 XC™ • S®-60 TRAX™ • S ®-65 TRAX™ 43Starting the EngineDiesel models1 At the ground controls, turn the key switch tothe desired position.2 Be sure both ground and platform control redEmergency Stop buttons are pulled out to theon position.The engine glow plugs will automatically startwhen the machine is turned on.3 At the ground controls: The LCDscreen will display the glow plugsymbol when the automatic glowplugs are on.4 At the platform controls: The glow plugindicator light will come on when the automaticglow plugs are on.5 When the glow plugs turn off, start the engine.Move and hold the engine start toggle switchor press and hold the engine start button.6 If the engine fails to start or dies, the restartdelay will disable the start switch for3 seconds.Emergency StopPush in the red Emergency Stop button to the offposition at the ground controls or the platformcontrols to stop all machine functions and turn theengine off.Repair any function that operates when either redEmergency Stop button is pushed in.Selecting and operating the ground controls willoverride the platform red Emergency Stop button.Emergency PowerUse emergency power if the primary power source(engine) fails.1 Turn the key switch to ground or platformcontrol.2 Pull out the red Emergency Stop button to theon position.3 Press down the foot switch when using thecontrols from the platform.4 Simultaneously push theemergency power button andactivate the desired function.The drive function will not operate with emergencypower.