41Configuration terminal problemsIf the configuration environment setup is correct, the configuration terminal displays boot informationwhen the router is powered on. If the setup is incorrect, the configuration terminal displays nothing orgarbled text.No terminal displaySymptomThe configuration terminal displays nothing when the router is powered on.SolutionTo resolve the problem:1. Verify that the power supply system is operating correctly.2. Verify that the console cable is correctly connected.3. Verify that the console cable is connected to the serial port that is configured for the configurationterminal.4. Verify that the configuration terminal parameters are configured as follows:{ Baud rate—9600{ Data bits—8{ Parity—none{ Stop bits—1{ Flow control—none5. Verify that the console cable is in good condition.6. If the problem persists, contact H3C Support.Garbled terminal displaySymptomThe configuration terminal displays garbled characters when the router is powered on.SolutionVerify that the Data bits field is set to 8 for the configuration terminal. If the Data bits field is set to 5 or6, the configuration terminal displays garbled characters.No response from the serial portSymptomNo boot information is displayed on the configuration terminal when the router starts up or restarts up.SolutionVerify that the serial cable is in good condition and the serial port settings are correct.