Operation Manual – NTPH3C S3600 Series Ethernet Switches-Release 1510 Chapter 1 NTP Configuration1-131.6 Displaying and Debugging NTPAfter the above configurations, you can execute display commands in any view todisplay the running status of switch, and verify the effect of the configurations.Table 1-7 Display and debug NTPOperation Command DescriptionDisplay the status of NTP services display ntp-service statusDisplay the information about thesessions maintained by NTPdisplay ntp-servicesessions [ verbose ]Display the brief information aboutNTP servers along the path fromthe local device to the referenceclock sourcedisplay ntp-service traceThe displaycommandscan beexecuted inany view1.7 Configuration Example1.7.1 Configuring NTP Server ModeI. Network requirementsThe local clock of H3C1 is set to the NTP master clock, with a stratum level of 2.Note:H3C1 is a switch that allows the local clock to serve as the NTP master clock.An S3600 Ethernet switch considers H3C1 as the NTP server and operates in clientmode, while H3C1 operates in server mode automatically.II. Network diagramH3C 11.0.1.11/241.0.1.S360012/24H3C 11.0.1.11/241.0.1.S360012/24Figure 1-6 Network diagram for the NTP server mode configurationIII. Configuration procedurePerform the following configurations on the S3600 switch.# View the NTP status of the S3600 switch before synchronization.