Wagenbouw HAPERT 355.2 TIPPING SYSTEM5.2.1 TIPPING RANGETipping range, tipping backwards To the end of the cylinderTipping range, tipping sideways (only typeCOBALT HM and COBALT+)Until the safety cable is tight or bymeans of a stop switch (electricoperation)5.2.2 HYDRAULIC PUMPHand pump COBALTHB, HM, and COBALT+Hand pump INDIGOHT and INDIGO LT(double-acting)Electric pump COBALT HB,HM, COBALT+ and INDIGOHTNominal pressure 180 bar 250 bar 170 barPressure relief valvesetting220 bar 300 bar 200 barOil reservoirVolumeEffective volume5 litres4.5 litres1 litre1 litre5 litres4.5 litresHydraulic oil Tellus 46, Shell HM46 orsimilarTellus 46, ShellHM46 or similarTellus 46, Shell HM46 orsimilarBatteryTypeCapacityN/A N/A12 V starter battery90 AhElectric motor capacity N/A N/A 2 kWMaximum sound level <70 dB(A) <70 dB(A) <70 dB(A)5.3 PHYSICAL CONDITIONS OF USEAmbient temperature:* Working* During transport/storage-5 to +40 degrees Celsius (withhydraulic system)-25 to +40 degrees Celsius-25 to +55 degrees CelsiusRelative humidity (RH) 30% to 95%, non-condensingLighting E4 / normal ambient lightingThe trailer is not suitable for use in an explosion-hazardous environment.