OperationSleep OperationUse of SLEEP functionOperation Mode1. In COOL,DRY modeSLEEP operation starts SLEEP operation stopsSLEEPoperation startsSLEEPoperation stopsApprox.6hrs1 hr1 hr1 hr3 hrs3 hrsRises 1 OCRises 1 O CRises 1O CTemp.settingTemp.settingUnit stopUnit stopIn COOL, DRY modeIn HEAT modeDecreases 2 OCDecreases 2 OC1 hr2.3.In HEAT modeIn AUTO mode4. In FAN modeIt has no SLEEP function.POWER/SOFT OperationBefore going to bed,you can simply press the SLEEPbutton and unit will operate in SLEEP mode and bringyou a sound sleep.After the unit starts,set the operation status,then press SLEEP button before which theclock must be adjusted and time being set.1 hours after SLEEP mode starts,temp.will become1 higher than temp.setting.After another 1 hours,temp.rises by 1 futher.The unit will run for further6 hours then stops Temp. is higher than temp.setting so that room temperature won’t be too lowfor your sleep.1 hours after SLEEP mode starts,temp willbecome 2 lower than temp.setting.Afteranother 1 hours,temp decrease by 2futher.After more another 3hours,temp.risesby 1 futher.The unit will run for further 3hours then stops.Temp.is lower than temp.setting so that room temperature won’t betoo high for your sleep.The unit operaters in corresponding sleep modeadapted to the automatically selected operationmode.O C OCO C OCO C4Power Failure Resume FunctionWhen TIMER function is set , the quiet sleepingfunction can't be set up. After the sleeping functionis set up, if user resets TIMER function, the sleepingfunction will be cancelled; the machine will be in thestate of timing-on, if the two modes are set up at thesame time, either of their operation time is endedfirst, the unit will stop automatically, and the othermode will be cancelled.When quiet sleeping function is set to 8 hours,the quiet sleeping time can not be adjusted.5.1. If the unit is started for the first time, the compressorwill not start running unless 3 minutes have elapsed.When the power resumes after power failure, the unit willrun automatically, and 3 minutes later the compressorstarts running.2. Note to the power failure resume:press the sleep button ten times in five seconds and enterthis function after hearing four sounds. And press the sleepbutton ten times within five seconds and leave this functionafter hearing two sounds.(1) POWER Operation(2) SOFT OperationWhen you need rapid heating or cooling, you can use this function.In COOL mode, fan speed automatically takes high speed ofAUTO fan mode. In HEAT mode, fan speed automatically takesmedium speed of AUTO fan mode.You can use this function when silence is needed for rest or reading.In SOFT operation mode, fan speed automatically takes low speedof AUTO fan mode.Note˖During POWER operation, in rapid HEAT or COOL modethe roomwill show uniform temperature distribution. Long periodSOFT operation will cause effect of not too cool or not too warm.To cancel POWER or SOFT operationPress POWER/SOFT button again, POWER or SOFT disappears.