WARNING:Use a cable of suitable length,Do not use tapped wires or an extension lead as this may causeoverheating, electric shocks, fire or explosion.All the cables shall have got the European authentication certificate. During installation, when theconnecting cables break off, it must be assured that the grouding wire is the last one to be broken off.If refrigerant gas leaks during installation, ventilate the area immediately.oxic gas may be producedAfter completing installation, check for refrigerant gas leakageWhen installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensureit is free of air, and use only the specified refrigerant (R32).Make sure ground connection is correct and reliable.Do not earth the unit to a utility pipe, lightningconductor or telephone earth lead. Imperfect earthing may result in electric shocks.Be sure to install an earth leakage circuit explosion-proof breaker.Do not use means to accelerate the defrosting process or to clean, other than those recommended bythe manufacturer.The breaker of the air conditioner should be all-pole switch and explosion-proof. The distancebetween its two contacts should not be no less than 3mm. Such means for disconnection must beincorporated in the wiring.Read the precautions in this manualcarefully before operating the unit. This appliance is filled with R32.Ask your dealer or qualified personnel to carry out installation work.Do not attempt to installthe air conditioner yourself. Improper Installation may result in water leakage, electric shocks, fire or explosion.Keep this manual where the user can easily nd it.Install the air conditioner in accordance with the instructions in this installation manualBe sure to use only the specified accessories and parts for installation work.Install the air conditioner on a foundation strong enough to withstand the weight of the unit.Electrical work must be performed in accordance with relevant local and national regulationsand with instructions in this installation manual,Be sure to use a dedicated power supply circuitonly. The wiring method should be in line with the local wiring standard.The type of connectingwire is H07RN-F..The appliance must be stored in a room without continuously operating ignition sources, the radius ofthe storage area should be no less than 2.5 m (for example:open flames, an operating gas applianceor an operating electric heater).Do not pierce or burn.Be aware that refrigerants may not contain an odour.Comply with national gas regulations.This appliance can be used by children aged 8 years and above and persons with reducedphysical, sensory or mental capabilities or lack of experience and knowledge if they havebeen given superivision or instruction concering use of the appliance in a safe way andunderstand the hazards involved. Children shall not play with the appliance. Cleaning anduser maintenance shall not be made by children without supervision.The air conditioner can not be discarded or scrapped RandomlyReusable mechanical connectors and flared joints are not allowed indoor.If you need please contactcustomer service personnel of Haier to scrap in order to obtain the correct disposal methods.g g gif the refrigerant comes into contact with fire,and explosion may be happen.The appliance must be installed, operated and stored in a room with a floor area larger than 3mThe room should be well ventilated.1